Development and validation of a rapid LC‐MS/MS method for the detection of 182 novel psychoactive substances in whole blood. Issue 2 (21st October 2021)
- Record Type:
- Journal Article
- Title:
- Development and validation of a rapid LC‐MS/MS method for the detection of 182 novel psychoactive substances in whole blood. Issue 2 (21st October 2021)
- Main Title:
- Development and validation of a rapid LC‐MS/MS method for the detection of 182 novel psychoactive substances in whole blood
- Authors:
- Giorgetti, Arianna
Barone, Rossella
Pelletti, Guido
Garagnani, Marco
Pascali, Jennifer
Haschimi, Belal
Auwärter, Volker - Abstract:
- Abstract: Introduction: The analysis of novel psychoactive substances (NPS) represents a challenge in forensic toxicology, due to the high number of compounds characterized by different structures and physicochemical properties both among different subclasses and within a single subclass of NPS. The aim of the present work is the development and validation of a targeted liquid chromatography tandem mass spectrometry (LC‐MS/MS) method for the detection of NPS in whole blood. Materials and methods: A protein‐precipitation based LC‐MS/MS method for the detection of more than 180 NPS was developed and validated by assessing the following parameters: selectivity, linearity, accuracy, precision, limit of detection (LOD) and of quantification (LOQ) recovery, and matrix effect. Then, the method was applied to real forensic samples. Results: The method allowed the identification of 132 synthetic cannabinoids, 22 synthetic opioids, and 28 substances among synthetic cathinones, stimulants, and other drugs. Validation was successfully achieved for most of the compounds. Linearity was in the range of 0.25–10 ng/ml for synthetic cannabinoids and 0.25–25 ng/ml for other drugs. Accuracy and precision were acceptable according to international guidelines. Three cases tested positive for fentanyl and ketamine, in the setting of emergency room administration. Conclusions: The present methodology represents a fast, not expensive, wide‐panel method for the analysis of more than 180 NPS byAbstract: Introduction: The analysis of novel psychoactive substances (NPS) represents a challenge in forensic toxicology, due to the high number of compounds characterized by different structures and physicochemical properties both among different subclasses and within a single subclass of NPS. The aim of the present work is the development and validation of a targeted liquid chromatography tandem mass spectrometry (LC‐MS/MS) method for the detection of NPS in whole blood. Materials and methods: A protein‐precipitation based LC‐MS/MS method for the detection of more than 180 NPS was developed and validated by assessing the following parameters: selectivity, linearity, accuracy, precision, limit of detection (LOD) and of quantification (LOQ) recovery, and matrix effect. Then, the method was applied to real forensic samples. Results: The method allowed the identification of 132 synthetic cannabinoids, 22 synthetic opioids, and 28 substances among synthetic cathinones, stimulants, and other drugs. Validation was successfully achieved for most of the compounds. Linearity was in the range of 0.25–10 ng/ml for synthetic cannabinoids and 0.25–25 ng/ml for other drugs. Accuracy and precision were acceptable according to international guidelines. Three cases tested positive for fentanyl and ketamine, in the setting of emergency room administration. Conclusions: The present methodology represents a fast, not expensive, wide‐panel method for the analysis of more than 180 NPS by LC‐MS/MS, which can be profitably applied both in a clinical context and in postmortem toxicology. Abstract : The study provides a method for the detection of more than 180 NPS pertaining to different subclasses. … (more)
- Is Part Of:
- Drug testing and analysis. Volume 14:Issue 2(2022)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 14:Issue 2(2022)
- Issue Display:
- Volume 14, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 14
- Issue:
- 2
- Issue Sort Value:
- 2022-0014-0002-0000
- Page Start:
- 202
- Page End:
- 223
- Publication Date:
- 2021-10-21
- Subjects:
- forensic toxicology -- mass spectrometry -- novel psychoactive substances -- screening method -- validation
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.3170 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26987.xml