A NOVEL APPROACH TO SCLERAL FIXATION OF POSTERIOR CHAMBER INTRAOCULAR LENSES AND CAPSULAR TENSION RINGS AND SEGMENTS IN DEEP-SET EYES. Issue Volume 16:Issues 3(2022) (28th February 2020)
- Record Type:
- Journal Article
- Title:
- A NOVEL APPROACH TO SCLERAL FIXATION OF POSTERIOR CHAMBER INTRAOCULAR LENSES AND CAPSULAR TENSION RINGS AND SEGMENTS IN DEEP-SET EYES. Issue Volume 16:Issues 3(2022) (28th February 2020)
- Main Title:
- A NOVEL APPROACH TO SCLERAL FIXATION OF POSTERIOR CHAMBER INTRAOCULAR LENSES AND CAPSULAR TENSION RINGS AND SEGMENTS IN DEEP-SET EYES
- Authors:
- Miller, Charles G.
Minkus, Caroline
Lyon, Alice T.
Basti, Surendra
Leskov, Ilya - Abstract:
- Abstract : The scleral fixation of posterior chamber intraocular lenses and capsular tension rings and segments present a unique surgical challenge in deep-set eyes. The Finesse FlexLoop (Alcon Laboratories) can be used as an alternative to 25-gauge forceps to more easily externalize Gore-Tex sutures in such cases. Abstract : Purpose: To demonstrate a novel approach to scleral fixation of posterior chamber intraocular lenses and capsular tension rings and segments in deep-set eyes using the Finesse FlexLoop (Alcon Laboratories). Methods: The technique described herein, based on previous approaches to scleral fixation of posterior chamber intraocular lenses, uniquely employs the FlexLoop to "lasso" Gore-Tex sutures that have already been threaded through the eyelets of a CZ70BD (Alcon Laboratories) IOL and externalize them. Results: All patients who underwent surgery with this technique experienced visual improvement. The only complication was of mild hyphema in the patient who had a capsular tension segment placed, which resolved with medical therapy. Conclusion: The advantages of this procedure include a smaller diameter instrument (FlexLoop) as compared to the 25-gauge forceps typically employed, an easier to perform surgical maneuver that alleviates the need for both precise placement and constant tension to be exerted by the surgeon to grasp the sutures, as well as an instrument that can function when bent up to 45° to help accommodate deep-set eyes requiring thisAbstract : The scleral fixation of posterior chamber intraocular lenses and capsular tension rings and segments present a unique surgical challenge in deep-set eyes. The Finesse FlexLoop (Alcon Laboratories) can be used as an alternative to 25-gauge forceps to more easily externalize Gore-Tex sutures in such cases. Abstract : Purpose: To demonstrate a novel approach to scleral fixation of posterior chamber intraocular lenses and capsular tension rings and segments in deep-set eyes using the Finesse FlexLoop (Alcon Laboratories). Methods: The technique described herein, based on previous approaches to scleral fixation of posterior chamber intraocular lenses, uniquely employs the FlexLoop to "lasso" Gore-Tex sutures that have already been threaded through the eyelets of a CZ70BD (Alcon Laboratories) IOL and externalize them. Results: All patients who underwent surgery with this technique experienced visual improvement. The only complication was of mild hyphema in the patient who had a capsular tension segment placed, which resolved with medical therapy. Conclusion: The advantages of this procedure include a smaller diameter instrument (FlexLoop) as compared to the 25-gauge forceps typically employed, an easier to perform surgical maneuver that alleviates the need for both precise placement and constant tension to be exerted by the surgeon to grasp the sutures, as well as an instrument that can function when bent up to 45° to help accommodate deep-set eyes requiring this procedure. … (more)
- Is Part Of:
- Retinal cases & brief reports. Volume 16:Issues 3(2022)
- Journal:
- Retinal cases & brief reports
- Issue:
- Volume 16:Issues 3(2022)
- Issue Display:
- Volume 16, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 16
- Issue:
- 3
- Issue Sort Value:
- 2022-0016-0003-0000
- Page Start:
- 379
- Page End:
- 381
- Publication Date:
- 2020-02-28
- Subjects:
- capsular tension ring -- capsular tension segment -- FlexLoop -- Hoffman pocket -- scleral fixation -- secondary IOL
Retina -- Diseases -- Periodicals
Retina -- Periodicals
Retinal Diseases -- Periodicals
Retina -- Case Reports
Retinal Diseases -- Case Reports
617.7 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01271216-000000000-00000 ↗
http://journals.lww.com/retinalcases/pages/default.aspx ↗
http://www.retinalcases.com ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/ICB.0000000000000988 ↗
- Languages:
- English
- ISSNs:
- 1935-1089
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26971.xml