Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups. Issue 3 (9th February 2023)
- Record Type:
- Journal Article
- Title:
- Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups. Issue 3 (9th February 2023)
- Main Title:
- Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups
- Authors:
- Boveda, Serge
Higuera, Lucas
Longacre, Colleen
Wolff, Claudia
Wherry, Kael
Stromberg, Kurt
El-Chami, Mikhael F - Abstract:
- Abstract: Aims: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. Methods and results: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4–5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48–0.95); diabetes, HR 0.69 (0.53–0.89); TVD, HR 0.60 (0.44–0.82); COPD, HR 0.73 (0.55–0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37–0.89); TVD, HR 0.46 (0.28–0.76); COPD, HR 0.51Abstract: Aims: This study compares clinical outcomes between leadless pacemakers (leadless-VVI) and transvenous ventricular pacemakers (transvenous ventricular permanent-VVI) in subgroups of patients at higher risk of pacemaker complications. Methods and results: This study is based on the Micra Coverage with Evidence Development (CED) study. Patients from the Micra CED study were considered in a high-risk subgroup if they had a diagnosis of chronic kidney disease Stages 4–5 (CKD45), end-stage renal disease, malignancy, diabetes, tricuspid valve disease (TVD), or chronic obstructive pulmonary disease (COPD) 12 months prior to pacemaker implant. A pre-specified set of complications and reinterventions were identified using diagnosis and procedure codes. Competing risks models were used to compare reinterventions and complications between leadless-VVI and transvenous-VVI patients within each subgroup; results were adjusted for multiple comparisons. A post hoc comparison of a composite outcome of reinterventions and device complications was conducted. Out of 27 991 patients, 9858 leadless-VVI and 12 157 transvenous-VVI patients have at least one high-risk comorbidity. Compared to transvenous-VVI patients, leadless-VVI patients in four subgroups [malignancy, HR 0.68 (0.48–0.95); diabetes, HR 0.69 (0.53–0.89); TVD, HR 0.60 (0.44–0.82); COPD, HR 0.73 (0.55–0.98)] had fewer complications, in three subgroups [diabetes, HR 0.58 (0.37–0.89); TVD, HR 0.46 (0.28–0.76); COPD, HR 0.51 (0.29–0.90)) had fewer reinterventions, and in four subgroups (malignancy, HR 0.52 (0.32–0.83); diabetes, HR 0.52 (0.35–0.77); TVD, HR 0.44 (0.28–0.70); COPD, HR 0.55 (0.34–0.89)] had lower rates of the combined outcome. Conclusion: In a real-world study, leadless pacemaker patients had lower 2-year complications and reinterventions rates compared with transvenous-VVI pacing in several high-risk subgroups. Trial Registration: ClinicalTrials.gov ID NCT03039712 Graphical Abstract: Graphical Abstract … (more)
- Is Part Of:
- Europace. Volume 25:Issue 3(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 3(2023)
- Issue Display:
- Volume 25, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2023-0025-0003-0000
- Page Start:
- 1041
- Page End:
- 1050
- Publication Date:
- 2023-02-09
- Subjects:
- Leadless pacemakers -- Transvenous pacemakers -- System reintervention -- Complications -- High-risk patients
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad016 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26978.xml