Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial. Issue 7616 (29th June 2007)
- Record Type:
- Journal Article
- Title:
- Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial. Issue 7616 (29th June 2007)
- Main Title:
- Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial
- Authors:
- Mant, Jonathan
Fitzmaurice, David A
Hobbs, F D Richard
Jowett, Sue
Murray, Ellen T
Holder, Roger
Davies, Michael
Lip, Gregory Y H - Abstract:
- Abstract : Objective To assess the accuracy of general practitioners, practice nurses, and interpretative software in the use of different types of electrocardiogram to diagnose atrial fibrillation. Design Prospective comparison with reference standard of assessment of electrocardiograms by two independent specialists. Setting 49 general practices in central England. Participants 2595 patients aged 65 or over screened for atrial fibrillation as part of the screening for atrial fibrillation in the elderly (SAFE) study; 49 general practitioners and 49 practice nurses. Interventions All electrocardiograms were read with the Biolog interpretative software, and a random sample of 12 lead, limb lead, and single lead thoracic placement electrocardiograms were assessed by general practitioners and practice nurses independently of each other and of the Biolog assessment. Main outcome measures Sensitivity, specificity, and positive and negative predictive values. Results General practitioners detected 79 out of 99 cases of atrial fibrillation on a 12 lead electrocardiogram (sensitivity 80%, 95% confidence interval 71% to 87%) and misinterpreted 114 out of 1355 cases of sinus rhythm as atrial fibrillation (specificity 92%, 90% to 93%). Practice nurses detected a similar proportion of cases of atrial fibrillation (sensitivity 77%, 67% to 85%), but had a lower specificity (85%, 83% to 87%). The interpretative software was significantly more accurate, with a specificity of 99%, but missedAbstract : Objective To assess the accuracy of general practitioners, practice nurses, and interpretative software in the use of different types of electrocardiogram to diagnose atrial fibrillation. Design Prospective comparison with reference standard of assessment of electrocardiograms by two independent specialists. Setting 49 general practices in central England. Participants 2595 patients aged 65 or over screened for atrial fibrillation as part of the screening for atrial fibrillation in the elderly (SAFE) study; 49 general practitioners and 49 practice nurses. Interventions All electrocardiograms were read with the Biolog interpretative software, and a random sample of 12 lead, limb lead, and single lead thoracic placement electrocardiograms were assessed by general practitioners and practice nurses independently of each other and of the Biolog assessment. Main outcome measures Sensitivity, specificity, and positive and negative predictive values. Results General practitioners detected 79 out of 99 cases of atrial fibrillation on a 12 lead electrocardiogram (sensitivity 80%, 95% confidence interval 71% to 87%) and misinterpreted 114 out of 1355 cases of sinus rhythm as atrial fibrillation (specificity 92%, 90% to 93%). Practice nurses detected a similar proportion of cases of atrial fibrillation (sensitivity 77%, 67% to 85%), but had a lower specificity (85%, 83% to 87%). The interpretative software was significantly more accurate, with a specificity of 99%, but missed 36 of 215 cases of atrial fibrillation (sensitivity 83%). Combining general practitioners' interpretation with the interpretative software led to a sensitivity of 92% and a specificity of 91%. Use of limb lead or single lead thoracic placement electrocardiograms resulted in some loss of specificity. Conclusions Many primary care professionals cannot accurately detect atrial fibrillation on an electrocardiogram, and interpretative software is not sufficiently accurate to circumvent this problem, even when combined with interpretation by a general practitioner. Diagnosis of atrial fibrillation in the community needs to factor in the reading of electrocardiograms by appropriately trained people. … (more)
- Is Part Of:
- BMJ. Volume 335:Issue 7616(2007)
- Journal:
- BMJ
- Issue:
- Volume 335:Issue 7616(2007)
- Issue Display:
- Volume 335, Issue 7616 (2007)
- Year:
- 2007
- Volume:
- 335
- Issue:
- 7616
- Issue Sort Value:
- 2007-0335-7616-0000
- Page Start:
- 380
- Page End:
- Publication Date:
- 2007-06-29
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Medicine
Periodicals
610 - Journal URLs:
- http://www.bmj.com/archive ↗
http://www.jstor.org/journals/09598138.html ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/3/ ↗
http://www.bmj.com/bmj/ ↗
http://www.bmj.com/archive ↗ - DOI:
- 10.1136/bmj.39227.551713.AE ↗
- Languages:
- English
- ISSNs:
- 0007-1447
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26975.xml