A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter. (May 2013)
- Record Type:
- Journal Article
- Title:
- A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter. (May 2013)
- Main Title:
- A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter
- Authors:
- Ginther, RM
Gorney, R
Cruz, R - Abstract:
- High-performance, low-prime-volume oxygenators for the pediatric patient population have become a growing market among manufacturers. In the summer of 2011, our institution clinically evaluated the performance of the newly released Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter. The static priming volume, including the integrated arterial filter, is 40 ml and the maximum rated blood flow is 1.5 liters per minute (LPM). The device was used on seven pediatric patients, ranging from 3.2 to 14 kg, undergoing various congenital heart defect repairs. Data were collected to calculate gas transfer, trans-oxygenator pressure drop, and heat exchange performance. The mean cardiopulmonary bypass time was 85 minutes and the mean cross-clamp time was 56 minutes. The average oxygen transfer was 34.3 ± 22.8 ml/O2 /min and increased with both blood flow and FiO2 . The average carbon dioxide transfer was 22.3 ± 17.8 ml/min and increased with both blood flow and gas sweep to blood flow ratio. The average trans-oxygenator pressure drop per blood flow was 53.3 ± 15.5 mmHg/L/min and increased with flow. The average heat exchanger performance factor was 47.6 ± 11.6% and decreased with flow. The heat exchange performance factor at maximum observed clinical flow, 1.42 LPM, was 36.4%. During this evaluation, the Maquet Quadrox-i Neonatal oxygenator adequately performed within its operational flow in the clinical setting.
- Is Part Of:
- Perfusion. Volume 28:Number 3(2013)
- Journal:
- Perfusion
- Issue:
- Volume 28:Number 3(2013)
- Issue Display:
- Volume 28, Issue 3 (2013)
- Year:
- 2013
- Volume:
- 28
- Issue:
- 3
- Issue Sort Value:
- 2013-0028-0003-0000
- Page Start:
- 194
- Page End:
- 199
- Publication Date:
- 2013-05
- Subjects:
- cardiopulmonary bypass -- pediatric oxygenator -- Quadrox- i neonatal oxygenator -- integrated arterial filter -- low prime oxygenator
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659113475694 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26977.xml