Robust RF shimming and small‐tip‐angle multispoke pulse design with finite‐difference regularization. Issue 3 (1st May 2021)
- Record Type:
- Journal Article
- Title:
- Robust RF shimming and small‐tip‐angle multispoke pulse design with finite‐difference regularization. Issue 3 (1st May 2021)
- Main Title:
- Robust RF shimming and small‐tip‐angle multispoke pulse design with finite‐difference regularization
- Authors:
- Paez, Adrian
Gu, Chunming
Cao, Zhipeng - Abstract:
- Abstract : Purpose: A new regularizer is proposed for the magnitude least‐squares optimization algorithm, to ensure robust parallel transmit RF shimming and small‐tip‐angle multispoke pulse designs for ultrahigh‐field MRI. Methods: A finite‐difference regularization term is activated as an additional regularizer in the iterative magnitude‐least‐squares based pulse design algorithm when an unwanted flip angle null distribution is detected. Both simulated and experimental B 1 + maps from different transmit arrays and different human subjects at 7 T were used to evaluate the proposed algorithm. The algorithm was further demonstrated in experiment with dynamic multislice RF shimming for a single‐shot gradient‐echo EPI for human functional MRI at 7 T. Results: The proposed finite‐difference regularizer effectively prevented excitation null to be formed for RF shimming and small‐tip‐angle multispoke pulses, and improved the latter with a monotonic trade‐off relationship between flip angle error and RF power. The proposed algorithm was demonstrated to be effective with several head‐array geometries by simulation and with a commercial head array with 12 healthy human subjects by experiment. During a functional MRI scan at 7 T with dynamic RF shimming, the proposed algorithm ensured high image SNR throughout the human brain, compared with near‐complete local signal loss by the conventional magnitude‐least‐squares algorithm. Conclusion: Using finite‐difference regularization to avoidAbstract : Purpose: A new regularizer is proposed for the magnitude least‐squares optimization algorithm, to ensure robust parallel transmit RF shimming and small‐tip‐angle multispoke pulse designs for ultrahigh‐field MRI. Methods: A finite‐difference regularization term is activated as an additional regularizer in the iterative magnitude‐least‐squares based pulse design algorithm when an unwanted flip angle null distribution is detected. Both simulated and experimental B 1 + maps from different transmit arrays and different human subjects at 7 T were used to evaluate the proposed algorithm. The algorithm was further demonstrated in experiment with dynamic multislice RF shimming for a single‐shot gradient‐echo EPI for human functional MRI at 7 T. Results: The proposed finite‐difference regularizer effectively prevented excitation null to be formed for RF shimming and small‐tip‐angle multispoke pulses, and improved the latter with a monotonic trade‐off relationship between flip angle error and RF power. The proposed algorithm was demonstrated to be effective with several head‐array geometries by simulation and with a commercial head array with 12 healthy human subjects by experiment. During a functional MRI scan at 7 T with dynamic RF shimming, the proposed algorithm ensured high image SNR throughout the human brain, compared with near‐complete local signal loss by the conventional magnitude‐least‐squares algorithm. Conclusion: Using finite‐difference regularization to avoid unwanted solutions, the robustness of RF shimming and small‐tip‐angle multispoke pulse design algorithms are improved, with better flip angle homogeneity and a monotonic trade‐off relationship between flip angle error and RF power. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 3(2021)
- Issue Display:
- Volume 86, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 3
- Issue Sort Value:
- 2021-0086-0003-0000
- Page Start:
- 1472
- Page End:
- 1481
- Publication Date:
- 2021-05-01
- Subjects:
- dynamic multislice shimming -- functional MRI -- parallel transmit -- small‐tip‐angle approximation -- spokes pulses -- ultrahigh‐field MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28820 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26953.xml