Accuracy of intraocular lens calculations in eyes with keratoconus. Issue 3 (28th March 2023)
- Record Type:
- Journal Article
- Title:
- Accuracy of intraocular lens calculations in eyes with keratoconus. Issue 3 (28th March 2023)
- Main Title:
- Accuracy of intraocular lens calculations in eyes with keratoconus
- Authors:
- Vandevenne, Magali M.S.
Webers, Valentijn S.C.
Segers, Maartje H.M.
Berendschot, Tos T.J.M.
Zadok, David
Dickman, Mor M.
Nuijts, Rudy M.M.A.
Abulafia, Adi - Abstract:
- Abstract : Recently, 2 keratoconus-adjusted formulas, Kane keratoconus and Barrett True-K for keratoconus, were introduced to calculate IOL power in patients with keratoconus. These formulas improve the prediction accuracy in patients with keratoconus. Abstract : Purpose: To compare the prediction accuracy of the Barrett True-K for keratoconus with standard formulas (SRK/T, Barrett Universal II, and Kane) and the Kane keratoconus formula. Setting: Shaare Zedek Medical Center, Jerusalem, Israel, and University Eye Clinic, Maastricht, the Netherlands. Design: Multicenter retrospective case series. Methods: Eyes with stable keratoconus undergoing cataract surgery were included. The predicted refractions were calculated for SRK/T, Barrett Universal II, Barrett True-K for keratoconus (predicted and measured), Kane, and Kane adjusted for keratoconus formulas. Primary outcomes were prediction error (PE), absolute error (AE), and percentage of eyes with PE ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Subgroup analyses were performed based on the severity of the keratoconus. Results: 57 eyes were included in the study. The PE was not significantly different from zero for SRK/T, Barrett True-K (predicted and measured), and Kane keratoconus formulas (range 0.09 to 0.22 D, P > .05). The AE of Barrett True-K predicted (median 0.14 D) and Barrett True-K measured (median 0.10 D) were significantly lower from Barrett Universal II (median 0.47 D) and Kane (median 0.50 D), P < .001. Conclusions:Abstract : Recently, 2 keratoconus-adjusted formulas, Kane keratoconus and Barrett True-K for keratoconus, were introduced to calculate IOL power in patients with keratoconus. These formulas improve the prediction accuracy in patients with keratoconus. Abstract : Purpose: To compare the prediction accuracy of the Barrett True-K for keratoconus with standard formulas (SRK/T, Barrett Universal II, and Kane) and the Kane keratoconus formula. Setting: Shaare Zedek Medical Center, Jerusalem, Israel, and University Eye Clinic, Maastricht, the Netherlands. Design: Multicenter retrospective case series. Methods: Eyes with stable keratoconus undergoing cataract surgery were included. The predicted refractions were calculated for SRK/T, Barrett Universal II, Barrett True-K for keratoconus (predicted and measured), Kane, and Kane adjusted for keratoconus formulas. Primary outcomes were prediction error (PE), absolute error (AE), and percentage of eyes with PE ±0.25 diopters (D), ±0.50 D, and ±1.00 D. Subgroup analyses were performed based on the severity of the keratoconus. Results: 57 eyes were included in the study. The PE was not significantly different from zero for SRK/T, Barrett True-K (predicted and measured), and Kane keratoconus formulas (range 0.09 to 0.22 D, P > .05). The AE of Barrett True-K predicted (median 0.14 D) and Barrett True-K measured (median 0.10 D) were significantly lower from Barrett Universal II (median 0.47 D) and Kane (median 0.50 D), P < .001. Conclusions: The Barrett True-K formulas for keratoconus had higher prediction accuracy as compared with new generation formulas and a similar prediction accuracy as compared with the Kane keratoconus formula. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 49:Issue 3(2023)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 49:Issue 3(2023)
- Issue Display:
- Volume 49, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 49
- Issue:
- 3
- Issue Sort Value:
- 2023-0049-0003-0000
- Page Start:
- 229
- Page End:
- 233
- Publication Date:
- 2023-03-28
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000001088 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26954.xml