Correction of sinus venosus atrial septal defects with the 10 zig covered Cheatham‐platinum stent – An international registry. Issue 1 (7th May 2021)
- Record Type:
- Journal Article
- Title:
- Correction of sinus venosus atrial septal defects with the 10 zig covered Cheatham‐platinum stent – An international registry. Issue 1 (7th May 2021)
- Main Title:
- Correction of sinus venosus atrial septal defects with the 10 zig covered Cheatham‐platinum stent – An international registry
- Authors:
- Rosenthal, Eric
Qureshi, Shakeel A.
Jones, Matthew
Butera, Gianfranco
Sivakumar, Kothandam
Boudjemline, Younes
Hijazi, Ziyad M.
Almaskary, Salim
Ponder, Reid D.
Salem, Morris M.
Walsh, Kevin
Kenny, Damien
Hascoet, Sebastien
Berman, Darren P.
Thomson, John
Vettukattil, Joseph J.
Zahn, Evan M. - Abstract:
- Abstract: Background: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC‐RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10‐zig covered Cheatham‐platinum (CCP) stent has the advantage of being available in lengths of 5–11 cm and dilatable to 34 mm in diameter. Methods: An international registry reviewed the outcomes of 10‐zig CCP stents in 75 patients aged 11.4–75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. Results: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). Conclusions: Ten‐zig CCPs of 7–8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulousAbstract: Background: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC‐RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10‐zig covered Cheatham‐platinum (CCP) stent has the advantage of being available in lengths of 5–11 cm and dilatable to 34 mm in diameter. Methods: An international registry reviewed the outcomes of 10‐zig CCP stents in 75 patients aged 11.4–75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. Results: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). Conclusions: Ten‐zig CCPs of 7–8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 98:Issue 1(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 98:Issue 1(2021)
- Issue Display:
- Volume 98, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 1
- Issue Sort Value:
- 2021-0098-0001-0000
- Page Start:
- 128
- Page End:
- 136
- Publication Date:
- 2021-05-07
- Subjects:
- covered stent -- congenital heart disease -- interventional catheterization -- sinus venosus ASD
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29750 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26945.xml