A likelihood‐based particle imaging filter using prior information. Issue 4 (18th February 2023)
- Record Type:
- Journal Article
- Title:
- A likelihood‐based particle imaging filter using prior information. Issue 4 (18th February 2023)
- Main Title:
- A likelihood‐based particle imaging filter using prior information
- Authors:
- Fullarton, Ryan
Volz, Lennart
Dikaios, Nikolaos
Schulte, Reinhard
Royle, Gary
Evans, Philip M.
Seco, Joao
Collins‐Fekete, Charles‐Antoine - Abstract:
- Abstract: Background: Particle imaging can increase precision in proton and ion therapy. Interactions with nuclei in the imaged object increase image noise and reduce image quality, especially for multinucleon ions that can fragment, such as helium. Purpose: This work proposes a particle imaging filter, referred to as the Prior Filter, based on using prior information in the form of an estimated relative stopping power (RSP) map and the principles of electromagnetic interaction, to identify particles that have undergone nuclear interaction. The particles identified as having undergone nuclear interactions are then excluded from the image reconstruction, reducing the image noise. Methods: The Prior Filter uses Fermi–Eyges scattering and Tschalär straggling theories to determine the likelihood that a particle only interacts electromagnetically. A threshold is then set to reject those particles with a low likelihood. The filter was evaluated and compared with a filter that estimates this likelihood based on the measured distribution of energy and scattering angle within pixels, commonly implemented as the 3σ filter. Reconstructed radiographs from simulated data of a 20‐cm water cylinder and an anthropomorphic chest phantom were generated with both protons and helium ions to assess the effect of the filters on noise reduction. The simulation also allowed assessment of secondary particle removal through the particle histories. Experimental data were acquired of the Catphan CTPAbstract: Background: Particle imaging can increase precision in proton and ion therapy. Interactions with nuclei in the imaged object increase image noise and reduce image quality, especially for multinucleon ions that can fragment, such as helium. Purpose: This work proposes a particle imaging filter, referred to as the Prior Filter, based on using prior information in the form of an estimated relative stopping power (RSP) map and the principles of electromagnetic interaction, to identify particles that have undergone nuclear interaction. The particles identified as having undergone nuclear interactions are then excluded from the image reconstruction, reducing the image noise. Methods: The Prior Filter uses Fermi–Eyges scattering and Tschalär straggling theories to determine the likelihood that a particle only interacts electromagnetically. A threshold is then set to reject those particles with a low likelihood. The filter was evaluated and compared with a filter that estimates this likelihood based on the measured distribution of energy and scattering angle within pixels, commonly implemented as the 3σ filter. Reconstructed radiographs from simulated data of a 20‐cm water cylinder and an anthropomorphic chest phantom were generated with both protons and helium ions to assess the effect of the filters on noise reduction. The simulation also allowed assessment of secondary particle removal through the particle histories. Experimental data were acquired of the Catphan CTP 404 Sensitometry phantom using the U.S. proton CT (pCT) collaboration prototype scanner. The proton and helium images were filtered with both the prior filtering method and a state‐of‐the‐art method including an implementation of the 3σ filter. For both cases, a dE‐E telescope filter, designed for this type of detector, was also applied. Results: The proton radiographs showed a small reduction in noise (1 mm of water‐equivalent thickness [WET]) but a larger reduction in helium radiographs (up to 5–6 mm of WET) due to better secondary filtering. The proton and helium CT images reflected this, with similar noise at the center of the phantom (0.02 RSP) for the proton images and an RSP noise of 0.03 for the proposed filter and 0.06 for the 3σ filter in the helium images. Images reconstructed from data with a dose reduction, up to a factor of 9, maintained a lower noise level using the Prior Filter over the state‐of‐the‐art filtering method. Conclusions: The proposed filter results in images with equal or reduced noise compared to those that have undergone a filtering method typical of current particle imaging studies. This work also demonstrates that the proposed filter maintains better performance against the state of the art with up to a nine‐fold dose reduction. … (more)
- Is Part Of:
- Medical physics. Volume 50:Issue 4(2023)
- Journal:
- Medical physics
- Issue:
- Volume 50:Issue 4(2023)
- Issue Display:
- Volume 50, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 50
- Issue:
- 4
- Issue Sort Value:
- 2023-0050-0004-0000
- Page Start:
- 2336
- Page End:
- 2353
- Publication Date:
- 2023-02-18
- Subjects:
- bespoke filter -- helium CT -- ion imaging -- noise reduction -- proton CT
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.16258 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26942.xml