809. Modified Laboratory Reporting to Prevent Catheter-Associated Urinary Tract Infections (CAUTIs). (31st December 2020)
- Record Type:
- Journal Article
- Title:
- 809. Modified Laboratory Reporting to Prevent Catheter-Associated Urinary Tract Infections (CAUTIs). (31st December 2020)
- Main Title:
- 809. Modified Laboratory Reporting to Prevent Catheter-Associated Urinary Tract Infections (CAUTIs)
- Authors:
- Monsalud, Cherie Faith
Singh, Kamaljit
McElvania, Erin
Schora, Donna
Grant, Jennifer
Lavin, Mary Alice
Lim, Rachel
Zelencik, Shane - Abstract:
- Abstract: Background: Catheter-associated urinary tract infections (CAUTIs) are among the most common healthcare-associated infections. Many patients at our institution with a CAUTI do not have signs or symptoms of infection and bacterial growth likely represents asymptomatic bacteriuria (ASB). As a result, we implemented a Modified Lab Workflow (MLW) focused on diagnostic stewardship to improve urine culture (UCx) reporting and prevent misclassification and unnecessary treatment of CAUTIs. Methods: On Sep. 1, 2019, laboratory reporting of Foley UCx was modified according to the protocol in Figure 1. UCx results were divided into 3 groups: (1) no growth, (2) mixed bacterial flora (≥3 organisms) not consistent with infection or (3) growth of ≤2 organisms with at least 1 organism ≥10 5 cfu/ml per National Healthcare Safety Network (NSHN) CAUTI definition. Group 3 UCx were resulted with instructions to the clinician (see Figure 1.). When requested, group 3 results were reviewed by Infection Prevention and released with organism identification and antibiotic susceptibility if it met Infectious Diseases Society of America (IDSA) CAUTI criteria. Otherwise they were resulted as: "Bacterial growth indicative of contamination or colonization." Figure 1. Modified Laboratory Workflow for Reporting Urine Cultures from Foley Catheters Results: Between Sep. 1, 2019 to Mar. 1, 2020, a total of 134 UCx from catheterized patients were reviewed. Forty-two (31%) of UCx were from patients withAbstract: Background: Catheter-associated urinary tract infections (CAUTIs) are among the most common healthcare-associated infections. Many patients at our institution with a CAUTI do not have signs or symptoms of infection and bacterial growth likely represents asymptomatic bacteriuria (ASB). As a result, we implemented a Modified Lab Workflow (MLW) focused on diagnostic stewardship to improve urine culture (UCx) reporting and prevent misclassification and unnecessary treatment of CAUTIs. Methods: On Sep. 1, 2019, laboratory reporting of Foley UCx was modified according to the protocol in Figure 1. UCx results were divided into 3 groups: (1) no growth, (2) mixed bacterial flora (≥3 organisms) not consistent with infection or (3) growth of ≤2 organisms with at least 1 organism ≥10 5 cfu/ml per National Healthcare Safety Network (NSHN) CAUTI definition. Group 3 UCx were resulted with instructions to the clinician (see Figure 1.). When requested, group 3 results were reviewed by Infection Prevention and released with organism identification and antibiotic susceptibility if it met Infectious Diseases Society of America (IDSA) CAUTI criteria. Otherwise they were resulted as: "Bacterial growth indicative of contamination or colonization." Figure 1. Modified Laboratory Workflow for Reporting Urine Cultures from Foley Catheters Results: Between Sep. 1, 2019 to Mar. 1, 2020, a total of 134 UCx from catheterized patients were reviewed. Forty-two (31%) of UCx were from patients with a Foley in-situ ≥48 hours and processed through MLW; 92 UCx were from a Foley in place < 48 hours and excluded from the study. Of the 42 UCx processed via MLW, 16 (38%) were no growth and 7 (17%) had bacterial growth suggestive of contamination. For group 3, 19/42 (45%) had growth of significant bacteria but only 1(5%) met IDSA criteria for reporting. During the study, 6 additional CAUTIs were reported due to incorrect specimen labeling causing Foley urine specimens to subvert MLW. Conclusion: During our study, we identified 1 CAUTI through apt MLW use. Seven total CAUTIs occurred (SIR=0.66); a majority due to incorrect UCx source labeling, resulting in missed MLW screening. Ten CAUTIs (SIR=0.97) were reported in the preceding 6 months. As part of a comprehensive CAUTI prevention program, a MLW can help reduce classification of ASB as a CAUTI. Education to providers on precise labeling of UCx source is a key component of a successful MLW. Disclosures: All Authors : No reported disclosures … (more)
- Is Part Of:
- Open forum infectious diseases. Volume 7:Number 1(2020) Supplement
- Journal:
- Open forum infectious diseases
- Issue:
- Volume 7:Number 1(2020) Supplement
- Issue Display:
- Volume 7, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 1
- Issue Sort Value:
- 2020-0007-0001-0000
- Page Start:
- S447
- Page End:
- S448
- Publication Date:
- 2020-12-31
- Subjects:
- Communicable diseases -- Periodicals
Medical microbiology -- Periodicals
Infection -- Periodicals
616.9 - Journal URLs:
- http://ofid.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/ofid/ofaa439.999 ↗
- Languages:
- English
- ISSNs:
- 2328-8957
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26916.xml