Intermuscular technique for implantation of the subcutaneous implantable defibrillator: a propensity-matched case–control study. Issue 4 (16th February 2023)
- Record Type:
- Journal Article
- Title:
- Intermuscular technique for implantation of the subcutaneous implantable defibrillator: a propensity-matched case–control study. Issue 4 (16th February 2023)
- Main Title:
- Intermuscular technique for implantation of the subcutaneous implantable defibrillator: a propensity-matched case–control study
- Authors:
- Botto, Giovanni Luca
Ziacchi, Matteo
Nigro, Gerardo
D'Onofrio, Antonio
Dello Russo, Antonio
Francia, Pietro
Viani, Stefano
Pisanò, Ennio
Bisignani, Giovanni
Caravati, Fabrizio
Migliore, Federico
De Filippo, Paolo
Ottaviano, Luca
Rordorf, Roberto
Manzo, Michele
Canevese, Fabio Lorenzo
Lovecchio, Mariolina
Valsecchi, Sergio
Checchi, Luca - Abstract:
- Abstract: Aims: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. Methods and results: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients ( n = 290) were propensity matched with patients of the IM group ( n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17–0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30–0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50–1.61, P = 0.721). There was noAbstract: Aims: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. Methods and results: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients ( n = 290) were propensity matched with patients of the IM group ( n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17–0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30–0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50–1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. Conclusion: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. Clinical trial registration: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637. Graphical Abstract: Graphical Abstract … (more)
- Is Part Of:
- Europace. Volume 25:Issue 4(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 4(2023)
- Issue Display:
- Volume 25, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2023-0025-0004-0000
- Page Start:
- 1423
- Page End:
- 1431
- Publication Date:
- 2023-02-16
- Subjects:
- Implantable defibrillator -- Subcutaneous -- Intermuscular technique -- Complication -- Inappropriate shock
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad028 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26924.xml