Usefulness of delivery catheter on accurate right ventricular septal pacing: Mt FUJI trial. Issue 4 (16th February 2023)
- Record Type:
- Journal Article
- Title:
- Usefulness of delivery catheter on accurate right ventricular septal pacing: Mt FUJI trial. Issue 4 (16th February 2023)
- Main Title:
- Usefulness of delivery catheter on accurate right ventricular septal pacing: Mt FUJI trial
- Authors:
- Naruse, Yoshihisa
Sano, Makoto
Kurebayashi, Nobutake
Morikawa, Shuji
Tsurumi, Naoki
Shiozawa, Tomoyuki
Takano, Shintaro
Ogano, Michio
Kimura, Kei
Miyajima, Keisuke
Sugiura, Ryo
Henmi, Ryuta
Muto, Masahiro
Hosoya, Natsuko
Hasebe, Hideyuki
Mizukami, Akira
Iguchi, Keisuke
Atsumi, Akiko
Odagiri, Keiichi
Kiyama, Yumi
Maekawa, Yuichiro - Abstract:
- Abstract: Aims: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. Methods and results: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. Results: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68–119) vs. 85 (59–118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). Conclusion: The delivery catheterAbstract: Aims: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. Methods and results: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. Results: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68–119) vs. 85 (59–118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). Conclusion: The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. Trial registration number: jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014 ) Graphical Abstract: Graphical Abstract Outcome comparison between delivery catheter and stylet systems. The delivery catheter system can achieve a higher RV lead placement on the RV septum success rate and a narrower paced QRS width than the stylet system. RV, right ventricular. … (more)
- Is Part Of:
- Europace. Volume 25:Issue 4(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 4(2023)
- Issue Display:
- Volume 25, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2023-0025-0004-0000
- Page Start:
- 1451
- Page End:
- 1457
- Publication Date:
- 2023-02-16
- Subjects:
- Pacemaker -- Atrioventricular block -- Right ventricular septal pacing -- Delivery catheter -- Stylet
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad027 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26924.xml