Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation. Issue 4 (7th March 2023)
- Record Type:
- Journal Article
- Title:
- Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation. Issue 4 (7th March 2023)
- Main Title:
- Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation
- Authors:
- Müller, Julian
Nentwich, Karin
Berkovitz, Artur
Ene, Elena
Sonne, Kai
Zhuravlev, Vitaly
Chakarov, Ivaylo
Barth, Sebastian
Waechter, Christian
Behnes, Michael
Halbfass, Philipp
Deneke, Thomas - Abstract:
- Abstract: Aims: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. Methods and results: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index–guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, andAbstract: Aims: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. Methods and results: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index–guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427–16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. Conclusion: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias. Graphical Abstract: Graphical Abstract … (more)
- Is Part Of:
- Europace. Volume 25:Issue 4(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 4(2023)
- Issue Display:
- Volume 25, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2023-0025-0004-0000
- Page Start:
- 1379
- Page End:
- 1391
- Publication Date:
- 2023-03-07
- Subjects:
- Ablation index -- Atrial fibrillation -- Endoscopically detected oesophageal lesions -- Pulmonary vein isolation -- High-power short-duration ablation -- Prognosis bull
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad053 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26924.xml