Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI. Issue 5 (8th May 2023)
- Record Type:
- Journal Article
- Title:
- Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI. Issue 5 (8th May 2023)
- Main Title:
- Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
- Authors:
- de Panafieu, Ariane
Lecler, Augustin
Goujon, Adrien
Krystal, Sidney
Gueguen, Antoine
Sadik, Jean-Claude
Savatovsky, Julien
Duron, Loïc - Abstract:
- Abstract : Background: Using reliable contrast-enhanced T1 sequences is crucial to detect enhancing brain lesions for multiple sclerosis (MS) at the time of diagnosis and over follow-up. Contrast-enhanced 3D gradient-recalled echo (GRE) T1-weighted imaging (WI) and 3D turbo spin echo (TSE) T1-WI are both available for clinical practice and have never been compared within the context of this diagnosis. Purpose: The aim of this study was to compare contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI for the detection of enhancing lesions in the brains of MS patients. Methods: This single-center prospective study enrolled patients with MS who underwent a 3.0 T brain MRI from August 2017 to April 2021 for follow-up. Contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI were acquired in randomized order. Two independent radiologists blinded to all data reported all contrast-enhanced lesions in each sequence. Their readings were compared with a reference standard established by a third expert neuroradiologist. Interobserver agreement, contrast ratio, and contrast-to-noise ratio were calculated for both sequences. Results: A total of 158 MS patients were included (mean age, 40 ± 11 years; 95 women). Significantly more patients had at least 1 contrast-enhanced lesion on 3D TSE T1-WI than on 3D GRE T1-WI for both readers (61/158 [38.6%] vs 48/158 [30.4%] and 60/158 [38.6%] vs 47/158 [29.7%], P < 0.001). Significantly more contrast-enhanced lesions per patient were detected on 3D TSE T1-WIAbstract : Background: Using reliable contrast-enhanced T1 sequences is crucial to detect enhancing brain lesions for multiple sclerosis (MS) at the time of diagnosis and over follow-up. Contrast-enhanced 3D gradient-recalled echo (GRE) T1-weighted imaging (WI) and 3D turbo spin echo (TSE) T1-WI are both available for clinical practice and have never been compared within the context of this diagnosis. Purpose: The aim of this study was to compare contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI for the detection of enhancing lesions in the brains of MS patients. Methods: This single-center prospective study enrolled patients with MS who underwent a 3.0 T brain MRI from August 2017 to April 2021 for follow-up. Contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI were acquired in randomized order. Two independent radiologists blinded to all data reported all contrast-enhanced lesions in each sequence. Their readings were compared with a reference standard established by a third expert neuroradiologist. Interobserver agreement, contrast ratio, and contrast-to-noise ratio were calculated for both sequences. Results: A total of 158 MS patients were included (mean age, 40 ± 11 years; 95 women). Significantly more patients had at least 1 contrast-enhanced lesion on 3D TSE T1-WI than on 3D GRE T1-WI for both readers (61/158 [38.6%] vs 48/158 [30.4%] and 60/158 [38.6%] vs 47/158 [29.7%], P < 0.001). Significantly more contrast-enhanced lesions per patient were detected on 3D TSE T1-WI (mean 2.47 vs 1.56 and 2.56 vs 1.39, respectively, P < 0.001). Interobserver agreement was excellent for both sequences, κ = 0.96 (confidence interval [CI], 0.91–1.00) for 3D TSE T1-WI and 0.92 (CI, 0.86–0.99) for 3D GRE T1-WI. Contrast ratio and contrast-to-noise ratio were significantly higher on 3D TSE T1-WI (0.84 vs 0.53, P < 0.001, and 87.9 vs 57.8, P = 0.03, respectively). Conclusions: At 3.0 T, contrast-enhanced 3D TSE-T1-WI supports the detection of significantly more enhancing lesions than 3D GRE T1-WI and should therefore be used for MS patients requiring contrast-enhanced examination. … (more)
- Is Part Of:
- Investigative radiology. Volume 58:Issue 5(2023)
- Journal:
- Investigative radiology
- Issue:
- Volume 58:Issue 5(2023)
- Issue Display:
- Volume 58, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 58
- Issue:
- 5
- Issue Sort Value:
- 2023-0058-0005-0000
- Page Start:
- 314
- Page End:
- 319
- Publication Date:
- 2023-05-08
- Subjects:
- brain MRI -- multiple sclerosis -- 3.0 T -- contrast-enhanced T1
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000937 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26909.xml