Standardized fractal bench test evaluation of coronary stents: Performances in bifurcation lesions treated by the re‐proximal optimization technique. Issue 1 (23rd September 2020)
- Record Type:
- Journal Article
- Title:
- Standardized fractal bench test evaluation of coronary stents: Performances in bifurcation lesions treated by the re‐proximal optimization technique. Issue 1 (23rd September 2020)
- Main Title:
- Standardized fractal bench test evaluation of coronary stents: Performances in bifurcation lesions treated by the re‐proximal optimization technique
- Authors:
- Piriou, Pierre‐Guillaume
Bonin, Mickael
Huchet, Francois
Letocart, Vincent
Manigold, Thibaut
Plessis, Julien
Derimay, Francois
Veziers, Joelle
Jordana, Fabienne
Guerin, Patrice - Abstract:
- Abstract: Background: Bifurcation lesions in coronary arteries are complex to treat with coronary stents, which are not designed for that purpose and can be unproperly deployed. Moreover, devices are constantly evolving, and so are angioplasty techniques. Objectives: The aim of this study was to determine the performances of different stents in the treatment of bifurcation lesions using the re‐proximal optimization technique (rePOT). Methods: Eleven stent platforms were evaluated: Xience Sierra (Abbott), Xience Alpine (Abbott), Synergy (Boston), Coroflex Isar (Bbraun), Cobra PzF (Celonova), Ultimaster (Terumo), Resolute Integrity (Medtronic), Resolute Onyx (Medtronic), Optimax (Hexacath), Orsiro (Biotronik), and Absorb (Abbott). Stents were deployed in a silicone fractal bifurcation model using the rePOT. Micro‐computed tomography was performed to assess side branch ostium coverage and strut malapposition, as well as the effect of rePOT on stent cell area. Results: Our study showed significant differences between stent platforms regarding side branch ostium coverage ( p = .002). The Synergy and Cobra PzF stents were the most performant devices to avoid ostium coverage. Strut malapposition varied significantly between devices ( p = .008) but the percentage of malapposed struts was relatively low. Significant differences were observed between stents regarding the cell area before ( p = .002) and also after rePOT ( p = .003), and the increase in cell area caused by rePOTAbstract: Background: Bifurcation lesions in coronary arteries are complex to treat with coronary stents, which are not designed for that purpose and can be unproperly deployed. Moreover, devices are constantly evolving, and so are angioplasty techniques. Objectives: The aim of this study was to determine the performances of different stents in the treatment of bifurcation lesions using the re‐proximal optimization technique (rePOT). Methods: Eleven stent platforms were evaluated: Xience Sierra (Abbott), Xience Alpine (Abbott), Synergy (Boston), Coroflex Isar (Bbraun), Cobra PzF (Celonova), Ultimaster (Terumo), Resolute Integrity (Medtronic), Resolute Onyx (Medtronic), Optimax (Hexacath), Orsiro (Biotronik), and Absorb (Abbott). Stents were deployed in a silicone fractal bifurcation model using the rePOT. Micro‐computed tomography was performed to assess side branch ostium coverage and strut malapposition, as well as the effect of rePOT on stent cell area. Results: Our study showed significant differences between stent platforms regarding side branch ostium coverage ( p = .002). The Synergy and Cobra PzF stents were the most performant devices to avoid ostium coverage. Strut malapposition varied significantly between devices ( p = .008) but the percentage of malapposed struts was relatively low. Significant differences were observed between stents regarding the cell area before ( p = .002) and also after rePOT ( p = .003), and the increase in cell area caused by rePOT varied considerably between devices ( p = .08). Conclusion: This study highlighted significant differences in the performances of stent platforms deployed in a fractal bifurcation model using rePOT, with a variable impact of the procedure on stent cell area. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 98:Issue 1(2021)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 98:Issue 1(2021)
- Issue Display:
- Volume 98, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 98
- Issue:
- 1
- Issue Sort Value:
- 2021-0098-0001-0000
- Page Start:
- E9
- Page End:
- E17
- Publication Date:
- 2020-09-23
- Subjects:
- fractal bench test -- malapposition -- ostium coverage -- POT‐side‐POT -- rePOT
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.29288 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26898.xml