Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation. Issue 2 (8th September 2021)
- Record Type:
- Journal Article
- Title:
- Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation. Issue 2 (8th September 2021)
- Main Title:
- Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation
- Authors:
- Patrono, Damiano
Cussa, Davide
Rigo, Federica
Romagnoli, Renato - Other Names:
- Angelico Roberta investigator.
Bellini Maria Irene investigator.
Bonaccorsi‐Riani Eliano investigator.
Brüggenwirth Isabel M. A. investigator.
Czigany Zoltan investigator.
De Carlis Riccardo investigator.
De Meijer Vincent E. investigator.
Dondossola Daniele investigator.
Eshmuminov Dilmurodjon investigator.
Ghinolfi Davide investigator.
Hessheimer Amelia J. investigator.
Kollmann Dagmar investigator.
Lai Quirino investigator.
Lurje Georg investigator.
Manzia Tommaso M. investigator.
Merhabi Arianeb investigator.
Melandro Fabio investigator.
Nasralla David investigator.
Nickkholgh Arash investigator.
Pagano Duilio investigator.
Rayar Michel investigator.
Saffioti Maria Cristina investigator.
Weissenbacher Annemarie investigator.
Avolio Alfonso W. investigator.
De Simone Paolo investigator.
Fondevila Costantino investigator.
Jassem Wayel investigator.
Macconmara Malcolm investigator.
Porte Robert J. investigator.
Ravaioli Matteo investigator.
Selzner Markus investigator.
Spada Marco investigator.
… (more) - Abstract:
- Abstract: Although machine perfusion (MP) is being increasingly adopted in liver transplantation, indications, timing, and modality are debated. To investigate current indications for MP a web‐based Google Forms survey was launched in January 2021 and addressed to 127 experts in the field, identified among first and corresponding Authors of MP literature in the last 10 years. The survey presented 10 real‐life cases of donor–recipient matching, asking whether the liver would be accepted (Q1), whether MP would be used in that particular setting (Q2) and, if so, by which MP modality (Q3) and at what timing during preservation (Q4). Respondents could also comment on each case. The agreement was evaluated using Krippendorff's alpha coefficient. Answers from 39 (30.1%) participants disclosed significant heterogeneity in graft acceptance, MP indications, technique, and timing. Agreement between respondents was generally poor (Q1, α = 0.11; Q2, α = 0.14; Q3, α = 0.12, Q4, α = 0.11). Overall, respondents preferred hypothermic MP and an end‐ischemic approach in 56.3% and 81.1% of cases, respectively. A total of 18 (46.2%) participants considered only one MP approach, whereas 17 (43.6%) and 3 (7.7%) considered using alternatively 2 or 3 different techniques. Of 38 comments, 17 (44.7%) were about the use of MP for graft viability assessment before implantation. This survey shows considerable variability in MP indications, emphasizing the need to identify scenarios of optimalAbstract: Although machine perfusion (MP) is being increasingly adopted in liver transplantation, indications, timing, and modality are debated. To investigate current indications for MP a web‐based Google Forms survey was launched in January 2021 and addressed to 127 experts in the field, identified among first and corresponding Authors of MP literature in the last 10 years. The survey presented 10 real‐life cases of donor–recipient matching, asking whether the liver would be accepted (Q1), whether MP would be used in that particular setting (Q2) and, if so, by which MP modality (Q3) and at what timing during preservation (Q4). Respondents could also comment on each case. The agreement was evaluated using Krippendorff's alpha coefficient. Answers from 39 (30.1%) participants disclosed significant heterogeneity in graft acceptance, MP indications, technique, and timing. Agreement between respondents was generally poor (Q1, α = 0.11; Q2, α = 0.14; Q3, α = 0.12, Q4, α = 0.11). Overall, respondents preferred hypothermic MP and an end‐ischemic approach in 56.3% and 81.1% of cases, respectively. A total of 18 (46.2%) participants considered only one MP approach, whereas 17 (43.6%) and 3 (7.7%) considered using alternatively 2 or 3 different techniques. Of 38 comments, 17 (44.7%) were about the use of MP for graft viability assessment before implantation. This survey shows considerable variability in MP indications, emphasizing the need to identify scenarios of optimal utilization for each technique. Viability assessment emerges as a fundamental need of transplant professionals when considering the use of MP. Abstract : In this survey, experts in the field of machine perfusion and liver transplantation were confronted to ten real‐world cases of donor‐recipient matching. Respondents were asked whether they would accept the offer and, if so, whether, how and when they would use machine perfusion for each case. The picture, which depicts each respondent answers, highlight significant heterogeneity with regards to graft acceptance and machine perfusion practice. … (more)
- Is Part Of:
- Artificial organs. Volume 46:Issue 2(2022)
- Journal:
- Artificial organs
- Issue:
- Volume 46:Issue 2(2022)
- Issue Display:
- Volume 46, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 46
- Issue:
- 2
- Issue Sort Value:
- 2022-0046-0002-0000
- Page Start:
- 296
- Page End:
- 305
- Publication Date:
- 2021-09-08
- Subjects:
- ex situ organ perfusion -- machine perfusion -- normothermic regional perfusion -- organ preservation -- viability assessment
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.14061 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26883.xml