Accuracy of the International Academy of Cytology Yokohama system of breast cytology reporting for fine needle aspiration biopsy of the breast in a dedicated breast care setting. Issue 2 (5th October 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of the International Academy of Cytology Yokohama system of breast cytology reporting for fine needle aspiration biopsy of the breast in a dedicated breast care setting. Issue 2 (5th October 2020)
- Main Title:
- Accuracy of the International Academy of Cytology Yokohama system of breast cytology reporting for fine needle aspiration biopsy of the breast in a dedicated breast care setting
- Authors:
- Agarwal, Akansha
Singh, Divya
Mehan, Anoushika
Paul, Pranoy
Puri, Neeti
Gupta, Priyanka
Syed, Anjum
Rao, Shalinee
Chowdhury, Nilotpal
Ravi, Bina - Abstract:
- Abstract: Background: The International Academy of Cytology (IAC) Yokohama system is a recently proposed system for reporting breast cytology by fine needle aspiration biopsies (FNAB). Multiple studies are needed to confirm the risk of malignancy (ROM) of the various reporting categories of this system. The present article studies the accuracy of the IAC Yokohama system in our center. Methods: Over a period of 1 year (September 2018‐August 2019), all cases of breast masses assessed by FNAB and histological correlation were studied retrospectively. Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) and overall accuracy of the IAC Yokohama system for diagnosing malignancy were assessed. The rates of malignancy (ROM) of each diagnostic category were also estimated. Results: Three hundred and twenty‐one FNABs had cyto‐histological correlation. The percent sensitivity (with 95% Confidence Intervals) when the atypical, suspicious of malignancy and the malignant categories were regarded as positive for malignancy were 98.2% [95.5%, 99.5%], 96.0% [92.5%, 98.2%], and 86.7% [81.5%, 90.8%] respectively. The percent specificity (with 95% Confidence intervals) for the same categories in the same order were 59.5% [47.4%, 70.7%], 91.9% [83.2%, 97.0%], and 100% [95.1%, 100%] respectively. The area under curve (AUC) for diagnosing malignancy was 0.981[0.963, 0.993]. The ROM for the benign, atypical, suspicious of malignancy and malignant categoryAbstract: Background: The International Academy of Cytology (IAC) Yokohama system is a recently proposed system for reporting breast cytology by fine needle aspiration biopsies (FNAB). Multiple studies are needed to confirm the risk of malignancy (ROM) of the various reporting categories of this system. The present article studies the accuracy of the IAC Yokohama system in our center. Methods: Over a period of 1 year (September 2018‐August 2019), all cases of breast masses assessed by FNAB and histological correlation were studied retrospectively. Sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) and overall accuracy of the IAC Yokohama system for diagnosing malignancy were assessed. The rates of malignancy (ROM) of each diagnostic category were also estimated. Results: Three hundred and twenty‐one FNABs had cyto‐histological correlation. The percent sensitivity (with 95% Confidence Intervals) when the atypical, suspicious of malignancy and the malignant categories were regarded as positive for malignancy were 98.2% [95.5%, 99.5%], 96.0% [92.5%, 98.2%], and 86.7% [81.5%, 90.8%] respectively. The percent specificity (with 95% Confidence intervals) for the same categories in the same order were 59.5% [47.4%, 70.7%], 91.9% [83.2%, 97.0%], and 100% [95.1%, 100%] respectively. The area under curve (AUC) for diagnosing malignancy was 0.981[0.963, 0.993]. The ROM for the benign, atypical, suspicious of malignancy and malignant category were 8.3% [2.3%, 20.0%], 17.2% [5.8%, 35.8%], 77.8% [57.7%, 91.4%], and 100% [98.1%, 100%] respectively. Conclusion: The IAC Yokohama system is suitable for accurately reporting breast lesions on FNAB. … (more)
- Is Part Of:
- Diagnostic cytopathology. Volume 49:Issue 2(2021)
- Journal:
- Diagnostic cytopathology
- Issue:
- Volume 49:Issue 2(2021)
- Issue Display:
- Volume 49, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 49
- Issue:
- 2
- Issue Sort Value:
- 2021-0049-0002-0000
- Page Start:
- 195
- Page End:
- 202
- Publication Date:
- 2020-10-05
- Subjects:
- IAC -- Yokohama system -- breast -- diagnostic accuracy -- fine needle aspiration -- fine needle biopsy -- Yokohama system
Cytodiagnosis -- Periodicals
Pathology, Cellular -- Periodicals
Cytology -- Periodicals
616.07582 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0339 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dc.24632 ↗
- Languages:
- English
- ISSNs:
- 8755-1039
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.656500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26884.xml