Refractive prediction error in cataract surgery using an optical biometer equipped with anterior segment OCT. Issue 4 (April 2022)
- Record Type:
- Journal Article
- Title:
- Refractive prediction error in cataract surgery using an optical biometer equipped with anterior segment OCT. Issue 4 (April 2022)
- Main Title:
- Refractive prediction error in cataract surgery using an optical biometer equipped with anterior segment OCT
- Authors:
- Kato, Yukihito
Kojima, Takashi
Tamaoki, Akeno
Ichikawa, Kei
Tamura, Kensei
Ichikawa, Kazuo - Abstract:
- Abstract : The optical biometer with anterior segment optical coherence tomography showed more myopic shifts in refractive prediction error than the golden standard optical biometer, but the results were clinically comparable. Abstract : Purpose: To evaluate refractive error after cataract surgery using an optical biometer equipped with anterior segment optical coherence tomography (AS-OCT). Setting: Chukyo Eye Clinic, Nagoya, Japan. Design: Retrospective observational design. Methods: In total, 150 patients with cataract (150 eyes, mean age 73.4 ± 8.2 years, men 76, women 74), who underwent measurement of parameters with the AS-OCT scanners ANTERION (AS-OCTB) and IOLMaster 700 (OCTB) before cataract surgery, were enrolled in the study. Refractive prediction error was compared between the 2 devices using the SRK/T, Haigis, and Barrett Universal II (UII) formulas for intraocular lens (IOL) power calculation. Results: There were significant differences between AS-OCTB and OCTB in axial length, mean corneal refractive power, anterior chamber depth, lens thickness, and corneal diameter (n = 150). In the SRK/T formula, the arithmetic means of refractive prediction errors for AS-OCTB and OCTB were −0.06 ± 0.46 diopters (D) and 0.02 ± 0.42 D, respectively. In the Haigis formula, the arithmetic means of refractive prediction errors for AS-OCTB and OCTB were −0.23 ± 0.40 D and −0.08 ± 0.35 D, respectively. In the Barrett UII formula, the arithmetic means of refractive predictionAbstract : The optical biometer with anterior segment optical coherence tomography showed more myopic shifts in refractive prediction error than the golden standard optical biometer, but the results were clinically comparable. Abstract : Purpose: To evaluate refractive error after cataract surgery using an optical biometer equipped with anterior segment optical coherence tomography (AS-OCT). Setting: Chukyo Eye Clinic, Nagoya, Japan. Design: Retrospective observational design. Methods: In total, 150 patients with cataract (150 eyes, mean age 73.4 ± 8.2 years, men 76, women 74), who underwent measurement of parameters with the AS-OCT scanners ANTERION (AS-OCTB) and IOLMaster 700 (OCTB) before cataract surgery, were enrolled in the study. Refractive prediction error was compared between the 2 devices using the SRK/T, Haigis, and Barrett Universal II (UII) formulas for intraocular lens (IOL) power calculation. Results: There were significant differences between AS-OCTB and OCTB in axial length, mean corneal refractive power, anterior chamber depth, lens thickness, and corneal diameter (n = 150). In the SRK/T formula, the arithmetic means of refractive prediction errors for AS-OCTB and OCTB were −0.06 ± 0.46 diopters (D) and 0.02 ± 0.42 D, respectively. In the Haigis formula, the arithmetic means of refractive prediction errors for AS-OCTB and OCTB were −0.23 ± 0.40 D and −0.08 ± 0.35 D, respectively. In the Barrett UII formula, the arithmetic means of refractive prediction errors for AS-OCTB and OCTB were −0.02 ± 0.38 D and 0.11 ± 0.36 D, respectively. AS-OCTB showed significantly larger refractive prediction error toward myopia than OCTB in all 3 formulas ( P < .0001). Conclusions: The refractive prediction error using AS-OCTB showed a small difference from that using OCTB. While clinically comparable, the 2 methods could drive meaningful differences in IOL selection. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 48:Issue 4(2022)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 48:Issue 4(2022)
- Issue Display:
- Volume 48, Issue 4 (2022)
- Year:
- 2022
- Volume:
- 48
- Issue:
- 4
- Issue Sort Value:
- 2022-0048-0004-0000
- Page Start:
- 429
- Page End:
- 434
- Publication Date:
- 2022-04
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/j.jcrs.0000000000000781 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26859.xml