Determination of ion recombination and polarity effects for the PTW Advanced Markus ionization chamber in synchrotron based scanned proton and carbon ion beams. (April 2022)
- Record Type:
- Journal Article
- Title:
- Determination of ion recombination and polarity effects for the PTW Advanced Markus ionization chamber in synchrotron based scanned proton and carbon ion beams. (April 2022)
- Main Title:
- Determination of ion recombination and polarity effects for the PTW Advanced Markus ionization chamber in synchrotron based scanned proton and carbon ion beams
- Authors:
- Mirandola, A.
Maestri, D.
Magro, G.
Mastella, E.
Molinelli, S.
Rossi, E.
Russo, S.
Vai, A.
Ciocca, M. - Abstract:
- Highlights: Ion recombination, polarity and charge multiplication effect. Carbon ions radiotherapy. High dose per fraction proton eye treatments. Dosimetry with small-gap plane-parallel ionization chamber. Abstract: The aim of this work was the investigation of the ion recombination and polarity factors ( ksat ad kpol ) for a PTW Advanced Markus ionization chamber exposed to proton and carbon ion beams at the Centro Nazionale di Adroterapia Oncologica. Measurements with protons were specifically dedicated for ocular treatments, in the low energy range and for small, collimated scanning fields. For both protons and carbon ions, several measurements were performed by delivering a 2D single energy layer of 3x3 cm 2 and homogeneous, biologically-optimized SOBPs. Data were collected at different depths in water, by varying the voltage values of the ionization chamber and for two different dose rates (the nominal one and one reduced to 20% of it). The ksat -values were determined from extrapolation of the saturation curves. Furthermore kpol -values were calculated using the recommendations from the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 Code of Practice. Results showed that the Advanced Markus performs optimally in this clinical scenario characterized by small treatment volumes and high dose gradients although for both particle types, but particularly for carbon ions, a charge multiplication effect up to 1.7% occurs at voltage higher thanHighlights: Ion recombination, polarity and charge multiplication effect. Carbon ions radiotherapy. High dose per fraction proton eye treatments. Dosimetry with small-gap plane-parallel ionization chamber. Abstract: The aim of this work was the investigation of the ion recombination and polarity factors ( ksat ad kpol ) for a PTW Advanced Markus ionization chamber exposed to proton and carbon ion beams at the Centro Nazionale di Adroterapia Oncologica. Measurements with protons were specifically dedicated for ocular treatments, in the low energy range and for small, collimated scanning fields. For both protons and carbon ions, several measurements were performed by delivering a 2D single energy layer of 3x3 cm 2 and homogeneous, biologically-optimized SOBPs. Data were collected at different depths in water, by varying the voltage values of the ionization chamber and for two different dose rates (the nominal one and one reduced to 20% of it). The ksat -values were determined from extrapolation of the saturation curves. Furthermore kpol -values were calculated using the recommendations from the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398 Code of Practice. Results showed that the Advanced Markus performs optimally in this clinical scenario characterized by small treatment volumes and high dose gradients although for both particle types, but particularly for carbon ions, a charge multiplication effect up to 1.7% occurs at voltage higher than 150 V. For protons, both the ion recombination and polarity corrections were always smaller than 0.3%, for all the analysed cases and adopted dose rates, so not affecting the dosimetric measurements for clinical routine. For carbon ions the polarity effect can be neglected while ion recombination has to be carefully calculated and cannot be neglected since corrections even higher than 1% can be found, especially at high LET measuring points. … (more)
- Is Part Of:
- Physica medica. Volume 96(2022)
- Journal:
- Physica medica
- Issue:
- Volume 96(2022)
- Issue Display:
- Volume 96, Issue 2022 (2022)
- Year:
- 2022
- Volume:
- 96
- Issue:
- 2022
- Issue Sort Value:
- 2022-0096-2022-0000
- Page Start:
- 149
- Page End:
- 156
- Publication Date:
- 2022-04
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2022.03.007 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26874.xml