Simultaneous determination of AM80 (tamibarotene) and WJD-A-1 in rat plasma by ultra high-performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study. (31st October 2018)
- Record Type:
- Journal Article
- Title:
- Simultaneous determination of AM80 (tamibarotene) and WJD-A-1 in rat plasma by ultra high-performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study. (31st October 2018)
- Main Title:
- Simultaneous determination of AM80 (tamibarotene) and WJD-A-1 in rat plasma by ultra high-performance liquid chromatography–tandem mass spectrometry and its application to a pharmacokinetic study
- Authors:
- Leng, Ping
Yang, Zhao
Ma, Baohua
Li, Jing
Sun, Jialin
Xie, Yiming
Sun, Yong - Abstract:
- Abstract: A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C18 column. The mobile phase consisted of methanol–0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40–5.40 × 10 3 and 5.08–5.08 × 10 3 ng/mL, respectively ( r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following anAbstract: A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C18 column. The mobile phase consisted of methanol–0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40–5.40 × 10 3 and 5.08–5.08 × 10 3 ng/mL, respectively ( r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following an intravenous administration of 300 μg/kg WJD-A-1 to rats. … (more)
- Is Part Of:
- Artificial cells, nanomedicine, and biotechnology. Volume 46(2018)Supplement 1
- Journal:
- Artificial cells, nanomedicine, and biotechnology
- Issue:
- Volume 46(2018)Supplement 1
- Issue Display:
- Volume 46, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2018-0046-0001-0000
- Page Start:
- 1131
- Page End:
- 1137
- Publication Date:
- 2018-10-31
- Subjects:
- AM80 (tamibarotene) -- WJD-A-1 -- UHPLC–MS/MS -- rat plasma -- pharmacokinetics
Artificial cells -- Periodicals
Nanotechnology -- Periodicals
Blood substitutes -- Periodicals
Tissue engineering -- Periodicals
Molecules -- Periodicals
Biotechnology -- Periodicals
615.39 - Journal URLs:
- http://informahealthcare.com/loi/abb?open=2012#id_2012 ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/21691401.2018.1446443 ↗
- Languages:
- English
- ISSNs:
- 2169-1401
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26872.xml