Retrospective motion correction through multi‐average k‐space data elimination (REMAKE) for free‐breathing cardiac cine imaging. Issue 6 (10th February 2023)
- Record Type:
- Journal Article
- Title:
- Retrospective motion correction through multi‐average k‐space data elimination (REMAKE) for free‐breathing cardiac cine imaging. Issue 6 (10th February 2023)
- Main Title:
- Retrospective motion correction through multi‐average k‐space data elimination (REMAKE) for free‐breathing cardiac cine imaging
- Authors:
- Neofytou, Alexander Paul
Neji, Radhouene
Kowalik, Grzegorz Tomasz
Mooiweer, Ronald
Wong, James
Fotaki, Anastasia
Ferreira, Joana
Evans, Carl
Bosio, Filippo
Mughal, Nabila
Razavi, Reza
Pushparajah, Kuberan
Roujol, Sébastien - Abstract:
- Abstract : Purpose: To develop a motion‐robust reconstruction technique for free‐breathing cine imaging with multiple averages. Method: Retrospective motion correction through multiple average k‐space data elimination (REMAKE) was developed using iterative removal of k‐space segments (from individual k‐space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k‐space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co‐registered, and averaged. Both techniques were validated against clinical "standard" signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free‐breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial‐blood contrast‐to‐noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed. Results: In phantom, motion artifacts using "standard" (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for "standard", p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for "standard", pAbstract : Purpose: To develop a motion‐robust reconstruction technique for free‐breathing cine imaging with multiple averages. Method: Retrospective motion correction through multiple average k‐space data elimination (REMAKE) was developed using iterative removal of k‐space segments (from individual k‐space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k‐space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co‐registered, and averaged. Both techniques were validated against clinical "standard" signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free‐breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial‐blood contrast‐to‐noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed. Results: In phantom, motion artifacts using "standard" (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for "standard", p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for "standard", p = 0.02/0.008), and a higher rate of diagnostic quality images (99%/100% vs. 94% for "standard"). Blood/myocardial SNR for "standard" (94 ± 30/33 ± 10) was higher vs. REMAKE (80 ± 25/28 ± 8, p = 0.002/0.005) and tended to be lower vs. REMAKE+ (105 ± 33/36 ± 12, p = 0.02/0.06). Myocardial‐blood CNR for "standard" (61 ± 22) was higher vs. REMAKE (53 ± 19, p = 0.003) and lower vs. REMAKE+ (69 ± 24, p = 0.007). Conclusions: Compared to "standard" signal averaging reconstruction, REMAKE and REMAKE+ provide improved myocardial sharpness, image quality, and rate of diagnostic quality images. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 89:Issue 6(2023)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 89:Issue 6(2023)
- Issue Display:
- Volume 89, Issue 6 (2023)
- Year:
- 2023
- Volume:
- 89
- Issue:
- 6
- Issue Sort Value:
- 2023-0089-0006-0000
- Page Start:
- 2242
- Page End:
- 2254
- Publication Date:
- 2023-02-10
- Subjects:
- 2D cine -- cardiac MRI -- free‐breathing -- retrospective respiratory motion correction
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.29613 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: