Optimal Hemodynamics and Risk of Severe Outcomes Post-Left Ventricular Assist Device Implantation. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Optimal Hemodynamics and Risk of Severe Outcomes Post-Left Ventricular Assist Device Implantation. Issue 3 (March 2022)
- Main Title:
- Optimal Hemodynamics and Risk of Severe Outcomes Post-Left Ventricular Assist Device Implantation
- Authors:
- Rosenbaum, Andrew N.
Ternus, Bradley W.
Stulak, John M.
Clavell, Alfredo L.
Schettle, Sarah D.
Behfar, Atta
Jentzer, Jacob C. - Abstract:
- Abstract : Data on pre-implant hemodynamic optimization before continuous flow left ventricular assist device placement (CF-LVAD) with respect to patient-centered outcomes remain limited. Consecutive patients undergoing CF-LVAD implant between 2007 and 2017 were identified. Hemodynamic variables, trends, and laboratory studies were evaluated pre-LVAD implant in a logistic regression model to identify predictors of the primary composite endpoint: the need for right ventricular assist device therapy, the requirement for hemodialysis at 90 days, and 30-day mortality. Multivariate modeling identified three variables significantly associated with the primary endpoint: right ventricular stroke work index (RVSWI), right atrial pressure (RAP), and blood urea nitrogen (BUN); all immediately pre-LVAD, p < 0.01. Optimal dichotomization points were 500 mmHg*ml*m −2, 12 mmHg, and 40 mg/dL. The three-component model identified an AUC of 0.77 ( p < 0.0001) for the composite endpoint. Optimization of 2/3 parameters, 1/3, and 0/3 was associated with odds ratios of 3.5 (95% CI, 1.1−11.7), 7.2 (95% CI, 2.1−24.2), and 20.6 (95% CI, 5.3−80.6), respectively, relative to those patients who were fully optimized (3/3 parameters). The number of optimized parameters was also associated with 1-year overall survival ( p = 0.02). Low RVSWI, high RAP, and high BUN were independently associated with adverse outcomes after the CF-LVAD implant, demonstrating a stepwise association with severe postimplantAbstract : Data on pre-implant hemodynamic optimization before continuous flow left ventricular assist device placement (CF-LVAD) with respect to patient-centered outcomes remain limited. Consecutive patients undergoing CF-LVAD implant between 2007 and 2017 were identified. Hemodynamic variables, trends, and laboratory studies were evaluated pre-LVAD implant in a logistic regression model to identify predictors of the primary composite endpoint: the need for right ventricular assist device therapy, the requirement for hemodialysis at 90 days, and 30-day mortality. Multivariate modeling identified three variables significantly associated with the primary endpoint: right ventricular stroke work index (RVSWI), right atrial pressure (RAP), and blood urea nitrogen (BUN); all immediately pre-LVAD, p < 0.01. Optimal dichotomization points were 500 mmHg*ml*m −2, 12 mmHg, and 40 mg/dL. The three-component model identified an AUC of 0.77 ( p < 0.0001) for the composite endpoint. Optimization of 2/3 parameters, 1/3, and 0/3 was associated with odds ratios of 3.5 (95% CI, 1.1−11.7), 7.2 (95% CI, 2.1−24.2), and 20.6 (95% CI, 5.3−80.6), respectively, relative to those patients who were fully optimized (3/3 parameters). The number of optimized parameters was also associated with 1-year overall survival ( p = 0.02). Low RVSWI, high RAP, and high BUN were independently associated with adverse outcomes after the CF-LVAD implant, demonstrating a stepwise association with severe postimplant adverse events. … (more)
- Is Part Of:
- ASAIO journal. Volume 68:Issue 3(2022)
- Journal:
- ASAIO journal
- Issue:
- Volume 68:Issue 3(2022)
- Issue Display:
- Volume 68, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 68
- Issue:
- 3
- Issue Sort Value:
- 2022-0068-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- left ventricular assist device -- LVAD -- optimization -- hemodynamics -- right ventricular failure -- dialysis -- Outcomes
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000001465 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26871.xml