Combined 23Na and 13C imaging at 3.0 Tesla using a single‐tuned large FOV birdcage coil. Issue 3 (2nd May 2021)
- Record Type:
- Journal Article
- Title:
- Combined 23Na and 13C imaging at 3.0 Tesla using a single‐tuned large FOV birdcage coil. Issue 3 (2nd May 2021)
- Main Title:
- Combined 23Na and 13C imaging at 3.0 Tesla using a single‐tuned large FOV birdcage coil
- Authors:
- Kaggie, Joshua D.
Lanz, Titus
McLean, Mary A.
Riemer, Frank
Schulte, Rolf F.
Benjamin, Arnold J. V.
Kessler, Dimitri A.
Sun, Chang
Gilbert, Fiona J.
Graves, Martin J.
Gallagher, Ferdia A. - Abstract:
- Abstract : Purpose: An unmet need in carbon‐13 ( 13 C)‐MRI is a transmit system that provides uniform excitation across a large FOV and can accommodate patients of wide‐ranging body habitus. Due to the small difference between the resonant frequencies, sodium‐23 ( 23 Na) coil developments can inform 13 C coil design while being simpler to assess due to the higher naturally abundant 23 Na signal. Here we present a removable 23 Na birdcage, which also allows operation as a 13 C abdominal coil. Methods: We demonstrate a quadrature‐driven 4‐rung 23 Na birdcage coil of 50 cm in length for both 23 Na and 13 C abdominal imaging. The coil transmit efficiencies and B 1 + maps were compared to a linearly driven 13 C Helmholtz‐based (clamshell) coil. SNR was investigated with 23 Na and 13 C data using an 8‐channel 13 C receive array within the 23 Na birdcage. Results: The 23 Na birdcage longitudinal FOV was > 40 cm, whereas the 13 C clamshell was < 32 cm. The transmit efficiency of the birdcage at the 23 Na frequency was 0.65 µT/sqrt(W), similar to the clamshell for 13 C. However, the coefficient of variation of 23 Na‐ B 1 + was 16%, nearly half that with the 13 C clamshell. The 8‐channel 13 C receive array combined with the 23 Na birdcage coil generated a greater than twofold increase in 23 Na‐SNR from the central abdomen compared with the birdcage alone. Discussion: This 23 Na birdcage coil has a larger FOV and improved B 1 + uniformity when compared to the widely used clamshell coilAbstract : Purpose: An unmet need in carbon‐13 ( 13 C)‐MRI is a transmit system that provides uniform excitation across a large FOV and can accommodate patients of wide‐ranging body habitus. Due to the small difference between the resonant frequencies, sodium‐23 ( 23 Na) coil developments can inform 13 C coil design while being simpler to assess due to the higher naturally abundant 23 Na signal. Here we present a removable 23 Na birdcage, which also allows operation as a 13 C abdominal coil. Methods: We demonstrate a quadrature‐driven 4‐rung 23 Na birdcage coil of 50 cm in length for both 23 Na and 13 C abdominal imaging. The coil transmit efficiencies and B 1 + maps were compared to a linearly driven 13 C Helmholtz‐based (clamshell) coil. SNR was investigated with 23 Na and 13 C data using an 8‐channel 13 C receive array within the 23 Na birdcage. Results: The 23 Na birdcage longitudinal FOV was > 40 cm, whereas the 13 C clamshell was < 32 cm. The transmit efficiency of the birdcage at the 23 Na frequency was 0.65 µT/sqrt(W), similar to the clamshell for 13 C. However, the coefficient of variation of 23 Na‐ B 1 + was 16%, nearly half that with the 13 C clamshell. The 8‐channel 13 C receive array combined with the 23 Na birdcage coil generated a greater than twofold increase in 23 Na‐SNR from the central abdomen compared with the birdcage alone. Discussion: This 23 Na birdcage coil has a larger FOV and improved B 1 + uniformity when compared to the widely used clamshell coil design while also providing similar transmit efficiency. The coil has the potential to be used for both 23 Na and 13 C imaging. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 3(2021)
- Issue Display:
- Volume 86, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 3
- Issue Sort Value:
- 2021-0086-0003-0000
- Page Start:
- 1734
- Page End:
- 1745
- Publication Date:
- 2021-05-02
- Subjects:
- body imaging -- carbon‐13 MRI -- multinuclear imaging -- RF coils -- sodium‐23 MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28772 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26845.xml