Analysis and mitigation of noise in simultaneous transmission and reception in MRI. Issue 3 (26th March 2021)
- Record Type:
- Journal Article
- Title:
- Analysis and mitigation of noise in simultaneous transmission and reception in MRI. Issue 3 (26th March 2021)
- Main Title:
- Analysis and mitigation of noise in simultaneous transmission and reception in MRI
- Authors:
- Tasdelen, Bilal
Sadeghi‐Tarakameh, Alireza
Yilmaz, Ugur
Atalar, Ergin - Abstract:
- Abstract : Purpose: In simultaneous transmission and reception (STAR) MRI, along with the coupling of the excitation pulse to the received signal, noise, and undesired distortions (spurs) coming from the transmit chain also leak into the acquired signal and degrade image quality. Here, properties of this coupled noise and its relationship with the transmit amplifier gain, transmit chain noise density, isolation performance, and imaging bandwidth are analyzed. It is demonstrated that by utilizing a recently proposed STAR technique, the transmit noise can be reduced. The importance of achieving high isolation and careful selection of the corresponding parameters are demonstrated. Theory and Methods: A cancellation algorithm, together with a vector modulator, is used for transmit‐receive isolation. The scanner is modeled as a pipeline of blocks to demonstrate the noise contribution from each block. With higher isolation, coupled transmit noise can be reduced to the point that the dominant noise source becomes acquisition noise, as in the case for pulsed MRI. Amplifiers with different gain and noise properties are used in the experiments to verify the derived noise‐transmit parameter relation. Results: With the proposed technique, more than 80 dB isolation in the analog domain is achieved. The leakage noise and the spurs coupled from the transmit chain, are reduced. It is shown that the transmit gain plays the most critical role in determining sufficient isolation, whereas theAbstract : Purpose: In simultaneous transmission and reception (STAR) MRI, along with the coupling of the excitation pulse to the received signal, noise, and undesired distortions (spurs) coming from the transmit chain also leak into the acquired signal and degrade image quality. Here, properties of this coupled noise and its relationship with the transmit amplifier gain, transmit chain noise density, isolation performance, and imaging bandwidth are analyzed. It is demonstrated that by utilizing a recently proposed STAR technique, the transmit noise can be reduced. The importance of achieving high isolation and careful selection of the corresponding parameters are demonstrated. Theory and Methods: A cancellation algorithm, together with a vector modulator, is used for transmit‐receive isolation. The scanner is modeled as a pipeline of blocks to demonstrate the noise contribution from each block. With higher isolation, coupled transmit noise can be reduced to the point that the dominant noise source becomes acquisition noise, as in the case for pulsed MRI. Amplifiers with different gain and noise properties are used in the experiments to verify the derived noise‐transmit parameter relation. Results: With the proposed technique, more than 80 dB isolation in the analog domain is achieved. The leakage noise and the spurs coupled from the transmit chain, are reduced. It is shown that the transmit gain plays the most critical role in determining sufficient isolation, whereas the amplifier noise figure does not contribute as much. Conclusion: The transmit noise and the spurs in STAR imaging are analyzed and mitigated by using a vector modulator. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 3(2021)
- Issue Display:
- Volume 86, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 3
- Issue Sort Value:
- 2021-0086-0003-0000
- Page Start:
- 1746
- Page End:
- 1758
- Publication Date:
- 2021-03-26
- Subjects:
- active cancellation -- receive noise -- STAR -- transmit noise
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28782 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26845.xml