Investigating the robustness of the AlignRT InBore™ co-calibration process and determining the overall tracking errors. (April 2023)
- Record Type:
- Journal Article
- Title:
- Investigating the robustness of the AlignRT InBore™ co-calibration process and determining the overall tracking errors. (April 2023)
- Main Title:
- Investigating the robustness of the AlignRT InBore™ co-calibration process and determining the overall tracking errors
- Authors:
- Nguyen, Daniel
Khodri, Mustapha
Sporea, Cristina
Reinoso, Rebeca
Jacob, Yannick
Farah, Jad - Abstract:
- Highlights: AlingRT InBore's ceiling and ring-mounted cameras co-calibration to Halcyon. Extrinsic and intrinsic overall calibration errors are determined. MV images-based calibration enables sub-millimetric accuracy. Laser-based calibration is insufficient for breast/SBRT DIBH procedures. Abstract: Objective: To determine the overall tracking errors inherent to the co-calibration procedure of AlignRT InBore™'s (Vision RT Ltd., London, UK) ceiling-mounted and ring-mounted cameras. Methods: Extrinsic calibration errors related to the mismatch between ceiling and InBore cameras' isocentres and treatment isocentre were determined using MV images and the SRS package and compared to traditional plate-based error. Next, using a realistic anthropomorphic female phantom, intrinsic calibration errors were determined while varying source-skin distance (80 to 100 cm), breast board inclination (0° to 12.5°), room lighting conditions (0 to 258 lx), skin colour (dark, white and natural skin colour), and pod occlusion. Results: MV images of the cube proved plate-based calibration to suffer from large errors especially in the vertical direction (up to 2 mm). Intrinsic calibration errors were considerably lower. Indeed, RTD values of ceiling and InBore cameras showed little variability with isocentre depth (within 1.0 mm/0.4°), surface orientation and breast board inclination (within 0.7 mm/0.3°), changing lighting conditions (within 0.1 mm/0.2°), skin colour/tone (within 0.3 mm/0.3°) andHighlights: AlingRT InBore's ceiling and ring-mounted cameras co-calibration to Halcyon. Extrinsic and intrinsic overall calibration errors are determined. MV images-based calibration enables sub-millimetric accuracy. Laser-based calibration is insufficient for breast/SBRT DIBH procedures. Abstract: Objective: To determine the overall tracking errors inherent to the co-calibration procedure of AlignRT InBore™'s (Vision RT Ltd., London, UK) ceiling-mounted and ring-mounted cameras. Methods: Extrinsic calibration errors related to the mismatch between ceiling and InBore cameras' isocentres and treatment isocentre were determined using MV images and the SRS package and compared to traditional plate-based error. Next, using a realistic anthropomorphic female phantom, intrinsic calibration errors were determined while varying source-skin distance (80 to 100 cm), breast board inclination (0° to 12.5°), room lighting conditions (0 to 258 lx), skin colour (dark, white and natural skin colour), and pod occlusion. Results: MV images of the cube proved plate-based calibration to suffer from large errors especially in the vertical direction (up to 2 mm). Intrinsic calibration errors were considerably lower. Indeed, RTD values of ceiling and InBore cameras showed little variability with isocentre depth (within 1.0 mm/0.4°), surface orientation and breast board inclination (within 0.7 mm/0.3°), changing lighting conditions (within 0.1 mm/0.2°), skin colour/tone (within 0.3 mm/0.3°) and camera pod occlusion (within 0.3 mm/0.2°). Conclusion: The use of MV-images proved critical to maintain co-calibrating errors of ceiling and InBore cameras to Halcyon's treatment isocentre below 1 mm. … (more)
- Is Part Of:
- Physica medica. Volume 108(2023)
- Journal:
- Physica medica
- Issue:
- Volume 108(2023)
- Issue Display:
- Volume 108, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 108
- Issue:
- 2023
- Issue Sort Value:
- 2023-0108-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-04
- Subjects:
- AlignRT Inbore™ -- Co-calibration -- MV calibration -- Closed-bore linacs -- SGRT
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2023.102567 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26836.xml