A standard system phantom for magnetic resonance imaging. Issue 3 (13th April 2021)
- Record Type:
- Journal Article
- Title:
- A standard system phantom for magnetic resonance imaging. Issue 3 (13th April 2021)
- Main Title:
- A standard system phantom for magnetic resonance imaging
- Authors:
- Stupic, Karl F.
Ainslie, Maureen
Boss, Michael A.
Charles, Cecil
Dienstfrey, Andrew M.
Evelhoch, Jeffrey L.
Finn, Paul
Gimbutas, Zydrunas
Gunter, Jeffrey L.
Hill, Derek L. G.
Jack, Clifford R.
Jackson, Edward F.
Karaulanov, Todor
Keenan, Kathryn E.
Liu, Guoying
Martin, Michele N.
Prasad, Pottumarthi V.
Rentz, Nikki S.
Yuan, Chun
Russek, Stephen E. - Abstract:
- Abstract : Purpose: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatialAbstract : Purpose: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. Conclusions: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 86:Issue 3(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 86:Issue 3(2021)
- Issue Display:
- Volume 86, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 86
- Issue:
- 3
- Issue Sort Value:
- 2021-0086-0003-0000
- Page Start:
- 1194
- Page End:
- 1211
- Publication Date:
- 2021-04-13
- Subjects:
- MRI standards -- phantom -- quality assurance -- quantitative MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28779 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26845.xml