Personalized 90Y-resin microspheres dose determination: a retrospective study on the impact of dosimetry software on the treatment of patients with selective internal radiotherapy. Issue 5 (3rd May 2023)
- Record Type:
- Journal Article
- Title:
- Personalized 90Y-resin microspheres dose determination: a retrospective study on the impact of dosimetry software on the treatment of patients with selective internal radiotherapy. Issue 5 (3rd May 2023)
- Main Title:
- Personalized 90Y-resin microspheres dose determination: a retrospective study on the impact of dosimetry software on the treatment of patients with selective internal radiotherapy
- Authors:
- Pinaquy, Jean-Baptiste
Lapuyade, Bruno
Blanc, Jean-Frederic
Hindié, Elif
Papadopoulos, Panteleimon
Debordeaux, Frederic - Abstract:
- Abstract : Introduction: The calculation of resin yttrium-90 ( 90 Y-) microspheres activity for selective internal radiotherapy (SIRT) needs to be investigated. Methods and materials: Analyses using Simplicit 90 Y (Boston Scientific, Natick, Massachusetts, USA) dosimetry software were performed to determine the concordance between the absorbed doses to the tumor (DT1 and DT2 ) and healthy liver (DN1 and DN2 ) during the pre-treatment and the post-treatment phases. An optimized calculation of the activity of 90 Y-microspheres performed using dosimetry software was applied retrospectively to assess the impact of this calculation method on the treatment. Results: DT1 ranged from 38.8 to 372 Gy, with a mean value of 128.9 ± 73.6 Gy and median of 121.2 Gy [interquartile range (IQR): 81.7–158.8 Gy]. The median DN1 and DN2 was 10.5 Gy (IQR: 5.8–17.6). A significant correlation was between DT1 and DT2 ( r = 0.88, P < 0.001) and DN1 and DN2 ( r = 0.96, P < 0.001). The optimized activities were calculated; the target dose to the tumor compartment was 120 Gy. No activity reduction was applied in accordance with the tolerance of the healthy liver. Optimization of the microspheres dosages would have resulted in a significant increase in activity for nine treatments (0.21–2.54 GBq) and a reduction for seven others (0.25–0.76 GBq). Conclusions: The development of customized dosimetry software adapted to clinical practice makes it possible to use dosimetry to optimize the dosage forAbstract : Introduction: The calculation of resin yttrium-90 ( 90 Y-) microspheres activity for selective internal radiotherapy (SIRT) needs to be investigated. Methods and materials: Analyses using Simplicit 90 Y (Boston Scientific, Natick, Massachusetts, USA) dosimetry software were performed to determine the concordance between the absorbed doses to the tumor (DT1 and DT2 ) and healthy liver (DN1 and DN2 ) during the pre-treatment and the post-treatment phases. An optimized calculation of the activity of 90 Y-microspheres performed using dosimetry software was applied retrospectively to assess the impact of this calculation method on the treatment. Results: DT1 ranged from 38.8 to 372 Gy, with a mean value of 128.9 ± 73.6 Gy and median of 121.2 Gy [interquartile range (IQR): 81.7–158.8 Gy]. The median DN1 and DN2 was 10.5 Gy (IQR: 5.8–17.6). A significant correlation was between DT1 and DT2 ( r = 0.88, P < 0.001) and DN1 and DN2 ( r = 0.96, P < 0.001). The optimized activities were calculated; the target dose to the tumor compartment was 120 Gy. No activity reduction was applied in accordance with the tolerance of the healthy liver. Optimization of the microspheres dosages would have resulted in a significant increase in activity for nine treatments (0.21–2.54 GBq) and a reduction for seven others (0.25–0.76 GBq). Conclusions: The development of customized dosimetry software adapted to clinical practice makes it possible to use dosimetry to optimize the dosage for each patient. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 44:Issue 5(2023)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 44:Issue 5(2023)
- Issue Display:
- Volume 44, Issue 5 (2023)
- Year:
- 2023
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2023-0044-0005-0000
- Page Start:
- 358
- Page End:
- 365
- Publication Date:
- 2023-05-03
- Subjects:
- dosimetry software -- hepatocellular carcinoma -- Y-90 resin microspheres
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000001673 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26814.xml