Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study. Issue 3 (4th February 2023)
- Record Type:
- Journal Article
- Title:
- Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study. Issue 3 (4th February 2023)
- Main Title:
- Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
- Authors:
- Del Monte, Alvise
Almorad, Alexandre
Pannone, Luigi
Della Rocca, Domenico Giovanni
Bisignani, Antonio
Monaco, Cinzia
Mouram, Sahar
Ramak, Robbert
Gauthey, Anaïs
Overeinder, Ingrid
Bala, Gezim
Sorgente, Antonio
Ströker, Erwin
Sieira, Juan
Brugada, Pedro
La Meir, Mark
Chierchia, Gian-Battista
de Asmundis, Carlo - Abstract:
- Abstract: Aims: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. Methods and results: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperatureAbstract: Aims: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. Methods and results: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). Conclusion: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation. Graphical Abstract: Graphical Abstract … (more)
- Is Part Of:
- Europace. Volume 25:Issue 3(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 3(2023)
- Issue Display:
- Volume 25, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2023-0025-0003-0000
- Page Start:
- 896
- Page End:
- 904
- Publication Date:
- 2023-02-04
- Subjects:
- Atrial fibrillation -- Radiofrequency balloon -- Pulmonary vein isolation -- Radiofrequency ablation -- Catheter ablation -- Single-shot predictors
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad017 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26826.xml