Optimal Degree of Balloon-Expandable Transcatheter Valve Oversizing in Patients With Borderline Aortic Annulus Measurements: Insights From a Multicenter Real-World Experience. (21st March 2023)
- Record Type:
- Journal Article
- Title:
- Optimal Degree of Balloon-Expandable Transcatheter Valve Oversizing in Patients With Borderline Aortic Annulus Measurements: Insights From a Multicenter Real-World Experience. (21st March 2023)
- Main Title:
- Optimal Degree of Balloon-Expandable Transcatheter Valve Oversizing in Patients With Borderline Aortic Annulus Measurements: Insights From a Multicenter Real-World Experience
- Authors:
- Panagides, Vassili
Cheema, Asim N.
Urena, Marina
Nombela-Franco, Luis
Veiga-Fernandez, Gabriela
Vilalta, Victoria
Regueiro, Ander
Del Val, David
Asmarats, Lluis
del Trigo, Maria
Serra, Vicenç
Munoz-Garcia, Antonio
Rezaei, Effat
Himbert, Dominique
Tirado-Conte, Gabriela
de la Torre Hernandez, José M.
Fernandez-Nofrerias, Eduard
Cepas-Guillén, Pedro L.
Alfonso, Fernando
Gutierrez-Alonso, Lola
Oteo Domínguez, Juan Francisco
Belanech, Yassin
Paradis, Jean-Michel
Mesnier, Jules
Rodés-Cabau, Josep - Abstract:
- Abstract : Background: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. Methods: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm 2 . A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. Results: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39–3.65; P =0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11–3.09]; P =0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41–1.45]; P =0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) andAbstract : Background: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. Methods: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm 2 . A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. Results: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39–3.65; P =0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11–3.09]; P =0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41–1.45]; P =0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. Conclusions: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes. … (more)
- Is Part Of:
- Circulation. Volume 16:Number 3(2023)
- Journal:
- Circulation
- Issue:
- Volume 16:Number 3(2023)
- Issue Display:
- Volume 16, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 16
- Issue:
- 3
- Issue Sort Value:
- 2023-0016-0003-0000
- Page Start:
- e012554
- Page End:
- Publication Date:
- 2023-03-21
- Subjects:
- hemodynamics -- outcomes -- oversizing -- paravalvular aortic regurgitation -- permanent pacemaker implantation
Cardiovascular system -- Surgery -- Periodicals
Cardiovascular system -- Diseases -- Treatment -- Periodicals
616.105 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01337495-000000000-00000 ↗
http://circinterventions.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCINTERVENTIONS.122.012554 ↗
- Languages:
- English
- ISSNs:
- 1941-7640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262560
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26833.xml