Optical Flow Estimation Improves Automated Seizure Detection in Neonatal EEG. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Optical Flow Estimation Improves Automated Seizure Detection in Neonatal EEG. Issue 3 (March 2022)
- Main Title:
- Optical Flow Estimation Improves Automated Seizure Detection in Neonatal EEG
- Authors:
- Martin, Joel R.
Gabriel, Paolo G.
Gold, Jeffrey J.
Haas, Richard
Davis, Suzanne L.
Gonda, David D.
Sharpe, Cynthia
Wilson, Scott B.
Nierenberg, Nicolas C.
Scheuer, Mark L.
Wang, Sonya G. - Abstract:
- Abstract : Purpose: Existing automated seizure detection algorithms report sensitivities between 43% and 77% and specificities between 56% and 90%. The algorithms suffer from false alarms when applied to neonatal EEG because of the high degree of nurse handling and rhythmic patting used to soothe neonates. Computer vision technology that quantifies movement in real time could distinguish artifactual motion and improve automated neonatal seizure detection algorithms. Methods: The authors used video EEG recordings from 43 neonates undergoing monitoring for seizures as part of the NEOLEV2 clinical trial. The Persyst neonatal automated seizure detection algorithm ran in real time during study EEG acquisitions. Computer vision algorithms were applied to extract detailed accounts of artifactual movement of the neonate or people near the neonate though dense optical flow estimation. Results: Using the methods mentioned above, 197 periods of patting activity were identified and quantified, of which 45 generated false-positive automated seizure detection events. A binary patting detection algorithm was trained with a subset of 470 event videos. This supervised detection algorithm was applied to a testing subset of 187 event videos with 8 false-positive events, which resulted in a 24% reduction in false-positive automated seizure detections and a 50% reduction in false-positive events caused by neonatal care patting, while maintaining 11 of 12 true-positive seizure detection events.Abstract : Purpose: Existing automated seizure detection algorithms report sensitivities between 43% and 77% and specificities between 56% and 90%. The algorithms suffer from false alarms when applied to neonatal EEG because of the high degree of nurse handling and rhythmic patting used to soothe neonates. Computer vision technology that quantifies movement in real time could distinguish artifactual motion and improve automated neonatal seizure detection algorithms. Methods: The authors used video EEG recordings from 43 neonates undergoing monitoring for seizures as part of the NEOLEV2 clinical trial. The Persyst neonatal automated seizure detection algorithm ran in real time during study EEG acquisitions. Computer vision algorithms were applied to extract detailed accounts of artifactual movement of the neonate or people near the neonate though dense optical flow estimation. Results: Using the methods mentioned above, 197 periods of patting activity were identified and quantified, of which 45 generated false-positive automated seizure detection events. A binary patting detection algorithm was trained with a subset of 470 event videos. This supervised detection algorithm was applied to a testing subset of 187 event videos with 8 false-positive events, which resulted in a 24% reduction in false-positive automated seizure detections and a 50% reduction in false-positive events caused by neonatal care patting, while maintaining 11 of 12 true-positive seizure detection events. Conclusions: This work presents a novel approach to improving automated seizure detection algorithms used during neonatal video EEG monitoring. This artifact detection mechanism can improve the ability of a seizure detector algorithm to distinguish between artifact and true seizure activity. … (more)
- Is Part Of:
- Journal of clinical neurophysiology. Volume 39:Issue 3(2022)
- Journal:
- Journal of clinical neurophysiology
- Issue:
- Volume 39:Issue 3(2022)
- Issue Display:
- Volume 39, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2022-0039-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- Electroencephalogram -- Epilepsy monitoring -- Seizure -- Neonatal -- Seizure detection -- Optical flow -- Computer vision
Electroencephalography -- Periodicals
Neurophysiology -- Periodicals
Electroencephalography -- Periodicals
Electroencephalography
Periodicals
612.805 - Journal URLs:
- http://journals.lww.com/clinicalneurophys/pages/default.aspx ↗
http://www.clinicalneurophys.com ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00004691-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/WNP.0000000000000767 ↗
- Languages:
- English
- ISSNs:
- 0736-0258
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.578000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26787.xml