Reproducibility of Automated Breast Ultrasonography and Handheld Ultrasonography for Breast Lesion Size Measurement. Issue 1 (March 2022)
- Record Type:
- Journal Article
- Title:
- Reproducibility of Automated Breast Ultrasonography and Handheld Ultrasonography for Breast Lesion Size Measurement. Issue 1 (March 2022)
- Main Title:
- Reproducibility of Automated Breast Ultrasonography and Handheld Ultrasonography for Breast Lesion Size Measurement
- Authors:
- Park, Ko Woon
Ko, Eun Young
Park, Surin
Han, Boo-Kyung
Ko, Eun Sook
Choi, Ji Soo
Kwon, Mi-ri - Abstract:
- Abstract : Abstract: The purpose of our study was to evaluate the reproducibility of size measurement of breast lesions using automated breast ultrasonography (ABUS) compared with that with handheld ultrasonography (HHUS). Three breast radiologists performed HHUS and measured the lesions size in 2 different phantoms: lesions with various shape, size, and same stiffness (phantom 1) and lesions with same shape, size, and various stiffness (phantom 2). After 1 month, the same radiologists measured the lesion size of the same breast phantoms in the images obtained using ABUS. We evaluated interobserver variability between 3 radiologists in ABUS and HHUS, and intraobserver variability of radiologists between ABUS and HHUS. Intraclass correlation coefficient (ICC) was used in statistical analysis. The measured size of lesions on HHUS was slightly larger than that on ABUS in both phantom 1 and 2, although not statistically significant ( P = 0.314, P = 0.858). There were no significant differences in size measurements between the radiologists' measurements and the reference size in phantom 2 ( P = 0.862). The ICCs for the interobserver agreement between the 3 radiologists were 0.98 to 0.99 on ABUS and 0.99 to 1.00 on HHUS, respectively. The ICCs for the intraobserver agreement between ABUS and HHUS were 0.97 to 0.97 in phantom 1 and 0.98 to 0.99 in phantom 2. In conclusion, ABUS showed excellent interobserver and intraobserver agreement with HHUS in measuring size of the lesions,Abstract : Abstract: The purpose of our study was to evaluate the reproducibility of size measurement of breast lesions using automated breast ultrasonography (ABUS) compared with that with handheld ultrasonography (HHUS). Three breast radiologists performed HHUS and measured the lesions size in 2 different phantoms: lesions with various shape, size, and same stiffness (phantom 1) and lesions with same shape, size, and various stiffness (phantom 2). After 1 month, the same radiologists measured the lesion size of the same breast phantoms in the images obtained using ABUS. We evaluated interobserver variability between 3 radiologists in ABUS and HHUS, and intraobserver variability of radiologists between ABUS and HHUS. Intraclass correlation coefficient (ICC) was used in statistical analysis. The measured size of lesions on HHUS was slightly larger than that on ABUS in both phantom 1 and 2, although not statistically significant ( P = 0.314, P = 0.858). There were no significant differences in size measurements between the radiologists' measurements and the reference size in phantom 2 ( P = 0.862). The ICCs for the interobserver agreement between the 3 radiologists were 0.98 to 0.99 on ABUS and 0.99 to 1.00 on HHUS, respectively. The ICCs for the intraobserver agreement between ABUS and HHUS were 0.97 to 0.97 in phantom 1 and 0.98 to 0.99 in phantom 2. In conclusion, ABUS showed excellent interobserver and intraobserver agreement with HHUS in measuring size of the lesions, regardless of shape, size, and stiffness. Therefore, ABUS mixed with HHUS can be used reliably in following up breast lesions size. … (more)
- Is Part Of:
- Ultrasound quarterly. Volume 38:Issue 1(2022)
- Journal:
- Ultrasound quarterly
- Issue:
- Volume 38:Issue 1(2022)
- Issue Display:
- Volume 38, Issue 1 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2022-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- automated breast ultrasonography -- handheld ultrasonography -- phantoms -- size measurement
Diagnostic ultrasonic imaging -- Periodicals
616.07543 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.8.1a/ovidweb.cgi?&S=PNMHFPHPLADDOHNFNCOKGBDCMNJGAA00&Full+Text=S.sh.18.19.24.25%7c408%7cFull+Text ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RUQ.0000000000000568 ↗
- Languages:
- English
- ISSNs:
- 0894-8771
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9082.815550
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26797.xml