Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation. Issue 3 (7th February 2023)
- Record Type:
- Journal Article
- Title:
- Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation. Issue 3 (7th February 2023)
- Main Title:
- Accuracy of continuous photoplethysmography-based 1 min mean heart rate assessment during atrial fibrillation
- Authors:
- Hermans, Astrid N L
Isaksen*, Jonas L
Gawalko, Monika
Pluymaekers, Nikki A H A
van der Velden, Rachel M J
Snippe, Hilco
Evens, Stijn
De Witte, Glenn
Luermans, Justin G L M
Manninger, Martin
Lumens, Joost
Kanters, Jørgen K
Linz, Dominik - Abstract:
- Abstract: Aims: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. Methods and results: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessmentAbstract: Aims: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. Methods and results: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5–5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates ( P = 0.040). Conclusion: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm. Graphical Abstract: Graphical Abstract … (more)
- Is Part Of:
- Europace. Volume 25:Issue 3(2023)
- Journal:
- Europace
- Issue:
- Volume 25:Issue 3(2023)
- Issue Display:
- Volume 25, Issue 3 (2023)
- Year:
- 2023
- Volume:
- 25
- Issue:
- 3
- Issue Sort Value:
- 2023-0025-0003-0000
- Page Start:
- 835
- Page End:
- 844
- Publication Date:
- 2023-02-07
- Subjects:
- Persistent atrial fibrillation -- 1 min mean heart rate assessment -- Photoplethysmography -- Electrocardiography -- Mobile health
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euad011 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26802.xml