The influence of reference electrode in electrical impedance tomography. Issue 12 (December 2022)
- Record Type:
- Journal Article
- Title:
- The influence of reference electrode in electrical impedance tomography. Issue 12 (December 2022)
- Main Title:
- The influence of reference electrode in electrical impedance tomography
- Authors:
- Lin, Zhimin
Huang, Weixiang
Gao, Zhijun
Yang, Lin
Li, Yimin
Lu, Yu
Dai, Meng
Fu, Feng
Sang, Ling
Zhao, Zhanqi - Abstract:
- Abstract: Background: Some electrical impedance tomography (EIT) devices equip reference electrodes. In practice, it is not uncommon to observe high contact impedance for the reference electrode. The influence of bad contact reference electrode on data quality is unknown. The study aimed to investigate the influence of reference electrode on EIT image reconstruction. Methods: Thirty lung healthy volunteers were prospectively examined with EIT. The subjects were spontaneously breathing in supine position. Three scenarios were constructed: 1. Normal measurement; 2. Reference electrode disconnected without recalibration; 3. Reference electrode disconnected, and the measurement restarted after recalibration of the system. EIT-based parameters measuring spatial and temporal ventilation distributions were calculated and compared. A so-call deviation score was calculated to assess the differences in EIT parameters between scenarios 2 and 1, between 3 and 1. Results: The absolute differences for all parameters were significantly higher than zero (p < 0.01 for all parameters and scenarios). Deviation score for scenario 2 was 4.5 ± 3.5. Four subjects had a deviation score of 0 in scenario 2 and five subjects had a score of 1. The deviation in scenario 3 was higher (6.1 ± 3.1). No subjects had a score of 0 and only two subjects had a score of 1. Conclusions: For EIT systems that equips with reference electrode, it is important to ensure the proper contact and functionality of theAbstract: Background: Some electrical impedance tomography (EIT) devices equip reference electrodes. In practice, it is not uncommon to observe high contact impedance for the reference electrode. The influence of bad contact reference electrode on data quality is unknown. The study aimed to investigate the influence of reference electrode on EIT image reconstruction. Methods: Thirty lung healthy volunteers were prospectively examined with EIT. The subjects were spontaneously breathing in supine position. Three scenarios were constructed: 1. Normal measurement; 2. Reference electrode disconnected without recalibration; 3. Reference electrode disconnected, and the measurement restarted after recalibration of the system. EIT-based parameters measuring spatial and temporal ventilation distributions were calculated and compared. A so-call deviation score was calculated to assess the differences in EIT parameters between scenarios 2 and 1, between 3 and 1. Results: The absolute differences for all parameters were significantly higher than zero (p < 0.01 for all parameters and scenarios). Deviation score for scenario 2 was 4.5 ± 3.5. Four subjects had a deviation score of 0 in scenario 2 and five subjects had a score of 1. The deviation in scenario 3 was higher (6.1 ± 3.1). No subjects had a score of 0 and only two subjects had a score of 1. Conclusions: For EIT systems that equips with reference electrode, it is important to ensure the proper contact and functionality of the reference electrode. The EIT data quality would remain unchanged in only a small portion of subjects. Abstract : Electrical impedance tomography; Reference electrode; Center of ventilation; Regions of interest; Respiratory rate; Global inhomogeneity index; Regional ventilation delay. … (more)
- Is Part Of:
- Heliyon. Volume 8:Issue 12(2022)
- Journal:
- Heliyon
- Issue:
- Volume 8:Issue 12(2022)
- Issue Display:
- Volume 8, Issue 12 (2022)
- Year:
- 2022
- Volume:
- 8
- Issue:
- 12
- Issue Sort Value:
- 2022-0008-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-12
- Subjects:
- Electrical impedance tomography -- Reference electrode -- Center of ventilation -- Regions of interest -- Respiratory rate -- Global inhomogeneity index -- Regional ventilation delay
Research -- Periodicals
Medical sciences -- Periodicals
Natural history -- Periodicals
Social sciences -- Periodicals
Earth sciences -- Periodicals
Physical sciences -- Periodicals
507.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/24058440/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.heliyon.2022.e12454 ↗
- Languages:
- English
- ISSNs:
- 2405-8440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26779.xml