Endobronchial ultrasound bronchoscopy Franseen fine needle biopsy tool versus standard fine needle aspiration needle: Impact on diagnosis and tissue adequacy. (March 2023)
- Record Type:
- Journal Article
- Title:
- Endobronchial ultrasound bronchoscopy Franseen fine needle biopsy tool versus standard fine needle aspiration needle: Impact on diagnosis and tissue adequacy. (March 2023)
- Main Title:
- Endobronchial ultrasound bronchoscopy Franseen fine needle biopsy tool versus standard fine needle aspiration needle: Impact on diagnosis and tissue adequacy
- Authors:
- Aboudara, Matthew C.
Saettele, Timothy
Tawfik, Ossama - Abstract:
- Abstract: Background: The Franseen fine needle biopsy tool (Acquire®, Boston Scientific, Boston, MA) may provide better quality specimens than current endobronchial ultrasound-transbronchial needle aspiration (EBUS-TNBA) needles. We performed a comparative retrospective study evaluating the diagnostic yield of the Franseen fine needle biopsy (FNB) versus standard fine needle aspiration (FNA) for benign lymphadenopathy and tissue acquisition for next generation sequencing (NGS) in non-small cell carcinoma (NSCLC). Methods: All EBUS-TBNA procedures performed between January 1st, 2019 to January 1st, 2020 where both the FNB needle and the FNA needle were used were analyzed. All demographic, procedural, and diagnostic data were recorded. The median tumor surface area, tumor cellularity and adequacy for NGS was evaluated for NSCLC specimens. Results: A total of 69 target lesions in 66 patients were biopsied with both the FNB and FNA needles. The mean (SD) size of target biopsied was 1.8 cm (0.8); The most common stations were 7 (54%) and 4R (26%). The mean (SD) needle passes were 6 (2.2) and 4 (1.8) with FNA and FNB needles, respectively (p < 0.0001). Benign lymphadenopathy was diagnosed with FNA needle in 46% and in 82% with FNB (p < 0.0001). NGS tissue adequacy was 47% with FNA needle versus 76% with FNB (p = 0.02). Median tumor surface area and tumor cellularity were greater with FNB needle than FNA needle (80 mm 2 versus 9 mm 2, p = 0.002, and 81% versus 45%, p = 0.0004).Abstract: Background: The Franseen fine needle biopsy tool (Acquire®, Boston Scientific, Boston, MA) may provide better quality specimens than current endobronchial ultrasound-transbronchial needle aspiration (EBUS-TNBA) needles. We performed a comparative retrospective study evaluating the diagnostic yield of the Franseen fine needle biopsy (FNB) versus standard fine needle aspiration (FNA) for benign lymphadenopathy and tissue acquisition for next generation sequencing (NGS) in non-small cell carcinoma (NSCLC). Methods: All EBUS-TBNA procedures performed between January 1st, 2019 to January 1st, 2020 where both the FNB needle and the FNA needle were used were analyzed. All demographic, procedural, and diagnostic data were recorded. The median tumor surface area, tumor cellularity and adequacy for NGS was evaluated for NSCLC specimens. Results: A total of 69 target lesions in 66 patients were biopsied with both the FNB and FNA needles. The mean (SD) size of target biopsied was 1.8 cm (0.8); The most common stations were 7 (54%) and 4R (26%). The mean (SD) needle passes were 6 (2.2) and 4 (1.8) with FNA and FNB needles, respectively (p < 0.0001). Benign lymphadenopathy was diagnosed with FNA needle in 46% and in 82% with FNB (p < 0.0001). NGS tissue adequacy was 47% with FNA needle versus 76% with FNB (p = 0.02). Median tumor surface area and tumor cellularity were greater with FNB needle than FNA needle (80 mm 2 versus 9 mm 2, p = 0.002, and 81% versus 45%, p = 0.0004). Conclusion: The FNB needle demonstrated higher diagnostic yield in benign lymphadenopathy and higher quality for NGS than standard FNA needle. Highlights: The Franseen EBUS core biopsy needle yielded a higher rate of benign diagnosis than that standard EBUS needle. Higher volumes of non-small cell carcinoma were obtained with the Franseen EBUS core biopsy needle than the standard EBUS needle. More adequate tissue for next generation sequencing was obtained with the Franseen EBUS core biopsy needle than the standard EBUS fine needle aspiration. … (more)
- Is Part Of:
- Respiratory medicine. Volume 208(2023)
- Journal:
- Respiratory medicine
- Issue:
- Volume 208(2023)
- Issue Display:
- Volume 208, Issue 2023 (2023)
- Year:
- 2023
- Volume:
- 208
- Issue:
- 2023
- Issue Sort Value:
- 2023-0208-2023-0000
- Page Start:
- Page End:
- Publication Date:
- 2023-03
- Subjects:
- Chest -- Diseases -- Periodicals
Chest -- Diseases -- Great Britain -- Periodicals
Respiratory organs -- Diseases -- Periodicals
Respiratory Tract Diseases -- Periodicals
Appareil respiratoire -- Maladies -- Périodiques
Thorax -- Maladies -- Périodiques
Appareil respiratoire -- Maladies -- Traitement -- Périodiques
Electronic journals
616.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09546111 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/09546111 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/09546111 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.rmed.2023.107131 ↗
- Languages:
- English
- ISSNs:
- 0954-6111
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7777.661900
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26777.xml