Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique. Issue 4 (17th March 2023)
- Record Type:
- Journal Article
- Title:
- Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique. Issue 4 (17th March 2023)
- Main Title:
- Mass-independent fractionation during Mo isotope measurement by MC-ICP-MS: implications for application of the double spike technique
- Authors:
- Zhao, Yan
Yang, Wubin
Leng, Chengbiao - Abstract:
- Abstract : This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS. Researchers should pay attention to the possible existence of instrument-related MIF during isotope measurement. Abstract : This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS and investigates its implication for the application of the double spike (DS) technique. A mixture of NIST SRM 3134 Mo solution with a calibrated 97 Mo– 100 Mo DS (1 : 1) was prepared for measurements over ∼15 h. The Mo isotopic data in this study show a good linear relationship in the scatter plots of ln( 97/95 Mo) vs. ln( 98/95 Mo), ln( 97/95 Mo) vs. ln( 100/95 Mo), and ln( 98/95 Mo) vs. ln( 100/95 Mo). Considering measurement errors on both vertical and horizontal axes, York linear regression was applied to linear fit. The slopes derived from the York linear regression are 1.33 ± 0.12 (2SE), 2.30 ± 0.20 (2SE), and 1.73 ± 0.14 (2SE), respectively. Given the error, the slopes are not exactly consistent with their theoretically expected values (1.49, 2.46, and 1.64) based on the assumption of mass-dependent fractionation (MDF). This study, for the first time, identifies MIF during Mo isotope measurement by MC-ICP-MS. DS calculation using theoretical mass fractionation factors shows that the analyzed NIST SRM 3134 Mo solution yielded δ 98/95 Mo values of 0.00 ± 0.04‰ (2SD, n = 17) relative to theAbstract : This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS. Researchers should pay attention to the possible existence of instrument-related MIF during isotope measurement. Abstract : This study presents our new observation on mass-independent fractionation (MIF) during Mo isotope measurement by MC-ICP-MS and investigates its implication for the application of the double spike (DS) technique. A mixture of NIST SRM 3134 Mo solution with a calibrated 97 Mo– 100 Mo DS (1 : 1) was prepared for measurements over ∼15 h. The Mo isotopic data in this study show a good linear relationship in the scatter plots of ln( 97/95 Mo) vs. ln( 98/95 Mo), ln( 97/95 Mo) vs. ln( 100/95 Mo), and ln( 98/95 Mo) vs. ln( 100/95 Mo). Considering measurement errors on both vertical and horizontal axes, York linear regression was applied to linear fit. The slopes derived from the York linear regression are 1.33 ± 0.12 (2SE), 2.30 ± 0.20 (2SE), and 1.73 ± 0.14 (2SE), respectively. Given the error, the slopes are not exactly consistent with their theoretically expected values (1.49, 2.46, and 1.64) based on the assumption of mass-dependent fractionation (MDF). This study, for the first time, identifies MIF during Mo isotope measurement by MC-ICP-MS. DS calculation using theoretical mass fractionation factors shows that the analyzed NIST SRM 3134 Mo solution yielded δ 98/95 Mo values of 0.00 ± 0.04‰ (2SD, n = 17) relative to the originally calibrated NIST SRM 3134 Mo. However, using experimental mass fractionation factors calculated from the slopes of line relationships, there is a deviation of about 0.46‰ for δ 98/95 Mo. The results indicate that the calibrated isotope ratios of the standard and DS could not be the true values but approximate values for better matching with the MDF-based equations. After DS calculation using experimental and theoretical mass fractionation factors, respectively, an additional standard-sample bracketing (SSB) method was conducted. Both calculations gave identical and accurate δ 98/95 Mo values (0.00 ± 0.06‰), indicating that the SSB method is able to correct deviation from MIF during DS calculation. Accordingly, we proposed that an additional SSB method is recommended to acquire accurate isotope ratios during the application of the DS technique. This study highlights that researchers should pay attention to the possible existence of instrument-related MIF during isotope measurement. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 38:Issue 4(2023)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 38:Issue 4(2023)
- Issue Display:
- Volume 38, Issue 4 (2023)
- Year:
- 2023
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2023-0038-0004-0000
- Page Start:
- 785
- Page End:
- 791
- Publication Date:
- 2023-03-17
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d2ja00427e ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26785.xml