A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers. (14th March 2022)
- Record Type:
- Journal Article
- Title:
- A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers. (14th March 2022)
- Main Title:
- A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
- Authors:
- Kowlgi, Gurukripa N.
Tseng, Andrew S.
Tempel, Nathan D.
Henrich, Mark J.
Venkatachalam, Kalpathi L.
Scott, Luis
Shen, Win‐Kuang
Deshmukh, Abhishek J.
Madhavan, Malini
Lee, Hon‐Chi
Asirvatham, Samuel J.
Friedman, Paul A.
Cha, Yong‐Mei
Mulpuru, Siva K. - Abstract:
- Abstract: Aims: The Micra TM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing Micra TM ‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing Micra TM ‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%. Results: Sixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up. Conclusion: With the increasing popularity of leadlessAbstract: Aims: The Micra TM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing Micra TM ‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing Micra TM ‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%. Results: Sixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up. Conclusion: With the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with Micra TM ‐AV devices. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 33:Number 5(2022)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 33:Number 5(2022)
- Issue Display:
- Volume 33, Issue 5 (2022)
- Year:
- 2022
- Volume:
- 33
- Issue:
- 5
- Issue Sort Value:
- 2022-0033-0005-0000
- Page Start:
- 982
- Page End:
- 993
- Publication Date:
- 2022-03-14
- Subjects:
- atrial fibrillation -- atrioventricular synchrony -- leadless pacemaker troubleshooting -- MicraTM transcatheter pacing system -- pacemaker syndrome
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15430 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26753.xml