Safety and feasibility of conduction system pacing in patients with congenital heart disease. (26th August 2021)
- Record Type:
- Journal Article
- Title:
- Safety and feasibility of conduction system pacing in patients with congenital heart disease. (26th August 2021)
- Main Title:
- Safety and feasibility of conduction system pacing in patients with congenital heart disease
- Authors:
- Cano, Óscar
Dandamudi, Gopi
Schaller, Robert D.
Pérez‐Roselló, Víctor
Ayala, Hebert D.
Izquierdo, Maite
Osca, Joaquín
Sancho‐Tello, María‐José
Rueda, Joaquín
Ruiz, Eladio
Insa, Beatriz
Martínez‐Dolz, Luis
Vijayaraman, Pugazhendhi - Abstract:
- Abstract: Introduction: Conduction system pacing (CSP) has emerged as an ideal physiologic pacing strategy for patients with permanent pacing indications. We sought to evaluate the safety and feasibility of CSP in a consecutive series of unselected patients with congenital heart disease (CHD). Methods: Consecutive patients with CHD in which CSP was attempted were included. Safety and feasibility, implant tools and electrical parameters at implant and at follow‐up were evaluated. Results: A total of 20 patients were included (10 with a previous device). A total of 10 patients had complex forms of CHD, 9 moderate defects and 1 a simple defect. CSP was achieved in 75% of cases (10 His bundle pacing, 5 left bundle branch pacing) with left ventricular septal pacing in the remaining 5 patients. Procedure times and fluoroscopy times were prolongued (126 ± 82 min and 27 ± 30 min, respectively). Ventricular lead implant times widely varied ranging from 4 to 115 min, (mean 31 ± 28 min) and the use of multiple delivery sheaths was frequent (50%). The QRS width was reduced from 145 ± 36 ms at baseline to 116 ± 18 ms with CSP. Implant electrical parameters included: CSP pacing threshold 0.95 ± 0.65 V; R wave amplitude 9.2 ± 8.8 mV and pacing impedance 632 ± 183 Ohms, and remained stable at a median follow‐up of 478 days (interquartile range: 225–567). Systemic ventricle systolic function and NYHA class (1.50 ± 0.51 vs. 1.10 ± 0.31; p = .008) significantly improved at follow‐up. LeadAbstract: Introduction: Conduction system pacing (CSP) has emerged as an ideal physiologic pacing strategy for patients with permanent pacing indications. We sought to evaluate the safety and feasibility of CSP in a consecutive series of unselected patients with congenital heart disease (CHD). Methods: Consecutive patients with CHD in which CSP was attempted were included. Safety and feasibility, implant tools and electrical parameters at implant and at follow‐up were evaluated. Results: A total of 20 patients were included (10 with a previous device). A total of 10 patients had complex forms of CHD, 9 moderate defects and 1 a simple defect. CSP was achieved in 75% of cases (10 His bundle pacing, 5 left bundle branch pacing) with left ventricular septal pacing in the remaining 5 patients. Procedure times and fluoroscopy times were prolongued (126 ± 82 min and 27 ± 30 min, respectively). Ventricular lead implant times widely varied ranging from 4 to 115 min, (mean 31 ± 28 min) and the use of multiple delivery sheaths was frequent (50%). The QRS width was reduced from 145 ± 36 ms at baseline to 116 ± 18 ms with CSP. Implant electrical parameters included: CSP pacing threshold 0.95 ± 0.65 V; R wave amplitude 9.2 ± 8.8 mV and pacing impedance 632 ± 183 Ohms, and remained stable at a median follow‐up of 478 days (interquartile range: 225–567). Systemic ventricle systolic function and NYHA class (1.50 ± 0.51 vs. 1.10 ± 0.31; p = .008) significantly improved at follow‐up. Lead revision was required in one patient at Day 4. Conclusions: Permanent CSP is safe and feasible in patients with CHD although implant technique is complex. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 10(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 10(2021)
- Issue Display:
- Volume 32, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 10
- Issue Sort Value:
- 2021-0032-0010-0000
- Page Start:
- 2692
- Page End:
- 2703
- Publication Date:
- 2021-08-26
- Subjects:
- conduction system pacing -- congenital heart disease -- His bundle pacing -- left bundle branch area pacing
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15213 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26754.xml