Utility of hot‐balloon‐based pulmonary vein isolation under balloon surface temperature monitoring: First clinical experience. (9th August 2021)
- Record Type:
- Journal Article
- Title:
- Utility of hot‐balloon‐based pulmonary vein isolation under balloon surface temperature monitoring: First clinical experience. (9th August 2021)
- Main Title:
- Utility of hot‐balloon‐based pulmonary vein isolation under balloon surface temperature monitoring: First clinical experience
- Authors:
- Nakahara, Shiro
Wakamatsu, Yuji
Fukuda, Reiko
Hori, Yuichi
Nishiyama, Naoki
Sato, Hirotsugu
Nagashima, Koichi
Mizutani, Yukiko
Ishikawa, Tetsuya
Kobayashi, Sayuki
Taguchi, Isao
Okumura, Yasuo - Abstract:
- Abstract: Introduction: A new hot balloon system that registers balloon surface temperature (BST) during energy delivery is now available for clinical use in Japan. This study sought to investigate the utility of BST measurement for achievement of pulmonary vein isolation (PVI) by a single‐shot energy delivery strategy during hot balloon ablation (HBA). Methods: We applied and tested the system in 30 consecutive patients undergoing HBA for paroxysmal or early‐persistent atrial fibrillation (AF). We also performed real‐time PV potential monitoring using a circular catheter. Results: Acute PVI was achieved with single hot balloon shots in 88% (106/120) of the PVs. Real‐time BSTs and PV potentials were recorded in all cases. Mean BST at documentation of PVI was 49.4°C, and acute reconnections were observed in most cases (86%, 12/14) in which the single‐shot technique was ineffective. Time‐to‐isolation (TTI) (23.1 ± 8.7 s vs. 36.3 ± 9.3 s, p < .01) and median BST (59.9 ± 2.6°C vs. 55.7 ± 1.9°C, p < .01) differed significantly between cases in which PVI was achieved (vs. those in which PVI was not achieved). Multivariable analysis revealed strong association between both TTI and median BST and acute PVI. The best median BST cutoff value for achieving PVI with a single shot was >58.7°C (sensitivity 67.0%, specificity 100%). Conclusion: Our data suggest that real‐time BST monitoring during energy applications is useful for predicting achievement of acute PVI by a single shotAbstract: Introduction: A new hot balloon system that registers balloon surface temperature (BST) during energy delivery is now available for clinical use in Japan. This study sought to investigate the utility of BST measurement for achievement of pulmonary vein isolation (PVI) by a single‐shot energy delivery strategy during hot balloon ablation (HBA). Methods: We applied and tested the system in 30 consecutive patients undergoing HBA for paroxysmal or early‐persistent atrial fibrillation (AF). We also performed real‐time PV potential monitoring using a circular catheter. Results: Acute PVI was achieved with single hot balloon shots in 88% (106/120) of the PVs. Real‐time BSTs and PV potentials were recorded in all cases. Mean BST at documentation of PVI was 49.4°C, and acute reconnections were observed in most cases (86%, 12/14) in which the single‐shot technique was ineffective. Time‐to‐isolation (TTI) (23.1 ± 8.7 s vs. 36.3 ± 9.3 s, p < .01) and median BST (59.9 ± 2.6°C vs. 55.7 ± 1.9°C, p < .01) differed significantly between cases in which PVI was achieved (vs. those in which PVI was not achieved). Multivariable analysis revealed strong association between both TTI and median BST and acute PVI. The best median BST cutoff value for achieving PVI with a single shot was >58.7°C (sensitivity 67.0%, specificity 100%). Conclusion: Our data suggest that real‐time BST monitoring during energy applications is useful for predicting achievement of acute PVI by a single shot during HBA. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 10(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 10(2021)
- Issue Display:
- Volume 32, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 10
- Issue Sort Value:
- 2021-0032-0010-0000
- Page Start:
- 2625
- Page End:
- 2635
- Publication Date:
- 2021-08-09
- Subjects:
- atrial fibrillation -- hot balloon -- pulmonary vein isolation
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.15196 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 26754.xml