Biomechanical Evaluation of Semi-rigid Junctional Fixation Using a Novel Cable Anchor System to Prevent Proximal Junctional Failure in Adult Spinal Deformity Surgery. Issue 9 (1st May 2022)
- Record Type:
- Journal Article
- Title:
- Biomechanical Evaluation of Semi-rigid Junctional Fixation Using a Novel Cable Anchor System to Prevent Proximal Junctional Failure in Adult Spinal Deformity Surgery. Issue 9 (1st May 2022)
- Main Title:
- Biomechanical Evaluation of Semi-rigid Junctional Fixation Using a Novel Cable Anchor System to Prevent Proximal Junctional Failure in Adult Spinal Deformity Surgery
- Authors:
- Doodkorte, Remco J.P.
Roth, Alex K.
Jacobs, Eva
Arts, Jacobus J.C.
Willems, Paul C. - Abstract:
- Abstract : A novel Cable Anchor was compared with other promising techniques in a biomechanical experiment to assess the potential as semi-rigid junctional fixation technique for adult spinal deformity surgery. The achievement of a gradual range of motion transition zone suggests the Cable Anchor may reduce the incidence of proximal junctional failure. Abstract : Study Design: A porcine cadaveric biomechanical study. Objective: To biomechanically evaluate a novel Cable Anchor System as semi-rigid junctional fixation technique for the prevention of proximal junctional failure after adult spinal deformity surgery and to make a comparison to alternative promising prophylactic techniques. Summary of Background Data: The abrupt change of stiffness at the proximal end of a pedicle screw construct is a major risk factor for the development of proximal junctional failure after adult spinal deformity surgery. A number of techniques that aim to provide a gradual transition zone in range of motion (ROM) at the proximal junction have previously been studied. In this study, the design of a novel Cable Anchor System, which comprises a polyethylene cable for rod fixation, is assessed. Methods: Ten T6–T13 porcine spine segments were subjected to cyclic 4 Nm pure-moment loading. The following conditions were tested: uninstrumented, 3 level pedicle screw fixation (PSF), and PSF with supplementary Cable Anchors applied proximally at 1-level (Anchor1) or 2-levels (Anchor2), transverse processAbstract : A novel Cable Anchor was compared with other promising techniques in a biomechanical experiment to assess the potential as semi-rigid junctional fixation technique for adult spinal deformity surgery. The achievement of a gradual range of motion transition zone suggests the Cable Anchor may reduce the incidence of proximal junctional failure. Abstract : Study Design: A porcine cadaveric biomechanical study. Objective: To biomechanically evaluate a novel Cable Anchor System as semi-rigid junctional fixation technique for the prevention of proximal junctional failure after adult spinal deformity surgery and to make a comparison to alternative promising prophylactic techniques. Summary of Background Data: The abrupt change of stiffness at the proximal end of a pedicle screw construct is a major risk factor for the development of proximal junctional failure after adult spinal deformity surgery. A number of techniques that aim to provide a gradual transition zone in range of motion (ROM) at the proximal junction have previously been studied. In this study, the design of a novel Cable Anchor System, which comprises a polyethylene cable for rod fixation, is assessed. Methods: Ten T6–T13 porcine spine segments were subjected to cyclic 4 Nm pure-moment loading. The following conditions were tested: uninstrumented, 3 level pedicle screw fixation (PSF), and PSF with supplementary Cable Anchors applied proximally at 1-level (Anchor1) or 2-levels (Anchor2), transverse process hooks (TPH), and 2-level sublaminar tapes (Tape2). The normalized segmental range of motion in the junctional zone was compared using one-way analysis of variance and linear regression. Results: Statistical comparison at the level proximal to PSF showed significantly lower ROMs for all techniques compared to PSF fixation alone in all movement directions. Linear regression demonstrated a higher linearity for Anchor1 (0.820) and Anchor2 (0.923) in the junctional zone in comparison to PSF (1-level: 0.529 and 2-level: 0.421). This linearity was similar to the compared techniques (TPH and Tape2). Conclusion: The Cable Anchor System presented in this study demonstrated a gradual ROM transition zone at the proximal end of a rigid pedicle screw construct similar to TPH and 2-level sublaminar tape semi-rigid junctional fixation constructs, while providing the benefit of preserving the posterior ligament complex. Level of Evidence: 5 … (more)
- Is Part Of:
- Spine. Volume 47:Issue 9(2022)
- Journal:
- Spine
- Issue:
- Volume 47:Issue 9(2022)
- Issue Display:
- Volume 47, Issue 9 (2022)
- Year:
- 2022
- Volume:
- 47
- Issue:
- 9
- Issue Sort Value:
- 2022-0047-0009-0000
- Page Start:
- E415
- Page End:
- E422
- Publication Date:
- 2022-05-01
- Subjects:
- adult spinal deformity -- proximal junctional failure -- proximal junctional kyphosis -- semi-rigid junctional fixation -- spine biomechanics
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000004228 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26745.xml