Seed‐based test–retest reliability of resting state functional magnetic resonance imaging at 3T and 7T. Issue 10 (14th September 2021)
- Record Type:
- Journal Article
- Title:
- Seed‐based test–retest reliability of resting state functional magnetic resonance imaging at 3T and 7T. Issue 10 (14th September 2021)
- Main Title:
- Seed‐based test–retest reliability of resting state functional magnetic resonance imaging at 3T and 7T
- Authors:
- Nemani, Ajay
Lowe, Mark J. - Abstract:
- Abstract: Purpose: Ultrahigh field (UHF) resting state functional magnetic resonance imaging (rsfMRI) has become increasingly available for clinical and basic research, bringing improvements in resolution and contrast over standard high field imaging. Despite these improvements, UHF connectivity studies present several challenges, including increased sensitivity to physiological confounds and a vastly increased data burden. We present a direct quantitative assessment of test–retest reliability of functional connectivity in several standard functional networks between subjects scanned at 3T and 7T. Methods: Five healthy subjects were scanned over four sessions each in a scan‐rescan design at both 3T and 7T field strengths. Resting state fMRI data were segmented into four major intrinsic connectivity networks, and seed‐based peak correlations within and between these networks examined. The reliability of these correlations was assessed using intra‐class correlation coefficients (ICC). Results: Across all data, over 4000 peak correlations were extracted for assessment. The reliability over all intrinsic networks was greater at 7T than 3T (median ICC 0.40 vs. 0.33, p ≤ 0.0014), with each network individually showing improvement. Inter‐network reliability was stronger than intra‐network reliability, but intra‐network reliability showed the greatest improvement between field strengths. Conclusion: We demonstrate significantly increased reliability of resting state connectivity atAbstract: Purpose: Ultrahigh field (UHF) resting state functional magnetic resonance imaging (rsfMRI) has become increasingly available for clinical and basic research, bringing improvements in resolution and contrast over standard high field imaging. Despite these improvements, UHF connectivity studies present several challenges, including increased sensitivity to physiological confounds and a vastly increased data burden. We present a direct quantitative assessment of test–retest reliability of functional connectivity in several standard functional networks between subjects scanned at 3T and 7T. Methods: Five healthy subjects were scanned over four sessions each in a scan‐rescan design at both 3T and 7T field strengths. Resting state fMRI data were segmented into four major intrinsic connectivity networks, and seed‐based peak correlations within and between these networks examined. The reliability of these correlations was assessed using intra‐class correlation coefficients (ICC). Results: Across all data, over 4000 peak correlations were extracted for assessment. The reliability over all intrinsic networks was greater at 7T than 3T (median ICC 0.40 vs. 0.33, p ≤ 0.0014), with each network individually showing improvement. Inter‐network reliability was stronger than intra‐network reliability, but intra‐network reliability showed the greatest improvement between field strengths. Conclusion: We demonstrate significantly increased reliability of resting state connectivity at UHF strengths over conventional field strengths using a novel hybrid seed‐based analysis. This result adds to the growing body of work supporting the migration of functional imaging studies to UHFs. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 10(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 10(2021)
- Issue Display:
- Volume 48, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2021-0048-0010-0000
- Page Start:
- 5756
- Page End:
- 5764
- Publication Date:
- 2021-09-14
- Subjects:
- 3 tesla -- 7 tesla -- functional connectivity -- reproducibility -- resting state fMRI -- test–retest reliability
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15210 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26765.xml