The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new‐onset atrial high‐rate episodes or subclinical atrial fibrillation: A systematic review and meta‐analysis. Issue 2 (15th January 2022)
- Record Type:
- Journal Article
- Title:
- The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new‐onset atrial high‐rate episodes or subclinical atrial fibrillation: A systematic review and meta‐analysis. Issue 2 (15th January 2022)
- Main Title:
- The utilization of atrial sensing dipole in single lead implantable cardioverter defibrillator for detection of new‐onset atrial high‐rate episodes or subclinical atrial fibrillation: A systematic review and meta‐analysis
- Authors:
- Pung, Xuanming
Hong, Daniel Zhihao
Ho, Tzyy Yeou
Shen, Xiayan
Tan, Pei Ting
Yeo, Colin
Tan, Vern Hsen - Abstract:
- Abstract: This meta‐analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD‐ICD) recipients in particular diagnosing new‐onset atrial high‐rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device‐detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single‐ and dual‐chamber ICD (VVI‐/DDD‐ICD) versus VDD‐ICD were included. Restricted maximum likelihood method for random effect model and Mantel‐Haenszel method for fixed effect model were used to estimate the effect size of new‐onset AHREs, or SCAF detection in each group. Three prospective studies were identified and total of 991 participants were included. There were 330 (33.3%) in VDD‐ICD and 661 (66.7%) in VVI‐/DDD‐ICD. Most (78%) participants were men. Median follow‐up was from 365 days to 847 days. VDD‐ICD has a higher likelihood of detecting AHREs or SCAF as compared to VVI‐/DDD‐ICD [(OR random effect : 2.6; 95% CI: 1.2, 5.8; p = .018); I‐squared = 67.8%, p = .019]. This difference was more apparently seen in the comparison between VDD‐ICD and VVI‐ICD [(OR random effect: 3.8; 95% CI: 2.1, 6.6, p < .001), I‐squared = 0.0%, p = .518]. The result is same as fixed effect. Rate of AHREs detection observed in VDD‐ICD was not statistically different when compared to the only group with DDD‐ICD from SENSEAbstract: This meta‐analysis aims to evaluate the performance of atrial sensing dipole in single lead implantable cardioverter defibrillator (VDD‐ICD) recipients in particular diagnosing new‐onset atrial high‐rate episodes (AHREs) defined as rate threshold of 200 beats per minute, or subclinical atrial fibrillation (SCAF) defined as device‐detected AF without symptoms. We comprehensively searched PubMed, Embase, and ClinicalTrials.gov. Studies comparing contemporary single‐ and dual‐chamber ICD (VVI‐/DDD‐ICD) versus VDD‐ICD were included. Restricted maximum likelihood method for random effect model and Mantel‐Haenszel method for fixed effect model were used to estimate the effect size of new‐onset AHREs, or SCAF detection in each group. Three prospective studies were identified and total of 991 participants were included. There were 330 (33.3%) in VDD‐ICD and 661 (66.7%) in VVI‐/DDD‐ICD. Most (78%) participants were men. Median follow‐up was from 365 days to 847 days. VDD‐ICD has a higher likelihood of detecting AHREs or SCAF as compared to VVI‐/DDD‐ICD [(OR random effect : 2.6; 95% CI: 1.2, 5.8; p = .018); I‐squared = 67.8%, p = .019]. This difference was more apparently seen in the comparison between VDD‐ICD and VVI‐ICD [(OR random effect: 3.8; 95% CI: 2.1, 6.6, p < .001), I‐squared = 0.0%, p = .518]. The result is same as fixed effect. Rate of AHREs detection observed in VDD‐ICD was not statistically different when compared to the only group with DDD‐ICD from SENSE trial. In conclusion, this meta‐analysis reveals that the use of floating atrial sensing dipole in VDD‐ICD increases the detection of new‐onset AHREs or SCAF when compared to VVI‐ICD, with similar atrial sensing performance to DDD‐ICD. Abstract : This meta‐analysis reveals that the use of a floating atrial sensing dipole in VDD‐ICD increases the detection of new‐onset AHREs or SCAF when compared to VVI‐ICD alone, with similar atrial sensing performance to DDD‐ICD. However, longer follow‐up is needed to determine the reliability of the atrial sensing component in the VDD‐ICD. … (more)
- Is Part Of:
- Journal of arrhythmia. Volume 38:Issue 2(2022)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 38:Issue 2(2022)
- Issue Display:
- Volume 38, Issue 2 (2022)
- Year:
- 2022
- Volume:
- 38
- Issue:
- 2
- Issue Sort Value:
- 2022-0038-0002-0000
- Page Start:
- 177
- Page End:
- 186
- Publication Date:
- 2022-01-15
- Subjects:
- atrial high rate episodes -- atrial sensing dipole -- implantable cardiac defibrillator -- subclinical atrial fibrillation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/joa3.12675 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26739.xml