A dynamic susceptibility contrast MRI digital reference object for testing software with leakage correction: Effect of background simulation. Issue 10 (10th August 2021)
- Record Type:
- Journal Article
- Title:
- A dynamic susceptibility contrast MRI digital reference object for testing software with leakage correction: Effect of background simulation. Issue 10 (10th August 2021)
- Main Title:
- A dynamic susceptibility contrast MRI digital reference object for testing software with leakage correction: Effect of background simulation
- Authors:
- Chen, Henry Szu‐Meng
Jen, Mu‐Lan
Hou, Ping
Stafford, R. Jason
Liu, Ho‐Ling - Abstract:
- Abstract: Purpose: Dynamic susceptibility contrast (DSC)‐MRI is a perfusion imaging technique from which useful quantitative imaging biomarkers can be derived. Relative cerebral blood volume (rCBV) is such a biomarker commonly used for evaluating brain tumors. To account for the extravasation of contrast agents in tumors, post‐processing leakage correction is often applied to improve rCBV accuracy. Digital reference objects (DRO) are ideal for testing the post‐processing software, because the biophysical model used to generate the DRO can be matched to the one that the software uses. This study aims to develop DROs to validate the leakage correction of software using Weisskoff model and to examine the effect of background signal time curves that are required by the model. Methods: Three DROs were generated using the Weisskoff model, each composed of nine foreground lesion objects with combinations of different levels of rCBV and contrast leakage parameter (K2). Three types of background were implemented for these DROs: (1) a multi‐compartment brain‐like background, (2) a sphere background with a constant signal time curve, and (3) a sphere background with signal time curve identical to that of the brain‐like DRO's white matter (WM). The DROs were then analyzed with an FDA‐cleared software with and without leakage correction. Leakage correction was tested with and without brain segmentation. Results: Accuracy of leakage correction was able to be verified using the brain‐likeAbstract: Purpose: Dynamic susceptibility contrast (DSC)‐MRI is a perfusion imaging technique from which useful quantitative imaging biomarkers can be derived. Relative cerebral blood volume (rCBV) is such a biomarker commonly used for evaluating brain tumors. To account for the extravasation of contrast agents in tumors, post‐processing leakage correction is often applied to improve rCBV accuracy. Digital reference objects (DRO) are ideal for testing the post‐processing software, because the biophysical model used to generate the DRO can be matched to the one that the software uses. This study aims to develop DROs to validate the leakage correction of software using Weisskoff model and to examine the effect of background signal time curves that are required by the model. Methods: Three DROs were generated using the Weisskoff model, each composed of nine foreground lesion objects with combinations of different levels of rCBV and contrast leakage parameter (K2). Three types of background were implemented for these DROs: (1) a multi‐compartment brain‐like background, (2) a sphere background with a constant signal time curve, and (3) a sphere background with signal time curve identical to that of the brain‐like DRO's white matter (WM). The DROs were then analyzed with an FDA‐cleared software with and without leakage correction. Leakage correction was tested with and without brain segmentation. Results: Accuracy of leakage correction was able to be verified using the brain‐like phantom and the sphere phantom with WM background. The sphere with constant background did not perform well with leakage correction with or without brain segmentation. The DROs were able to verify that for the particular software tested, leakage correction with brain segmentation achieved the lowest error. Conclusions: DSC‐MRI DROs with biophysical model matched to that of the post‐processing software can be well used for the software's validation, provided that the background signals are also properly simulated for generating the reference time curve required by the model. Care needs to be taken to consider the interaction of the design of the DRO with the software's implementation of brain segmentation to extract the reference time curve. … (more)
- Is Part Of:
- Medical physics. Volume 48:Issue 10(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 10(2021)
- Issue Display:
- Volume 48, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2021-0048-0010-0000
- Page Start:
- 6051
- Page End:
- 6059
- Publication Date:
- 2021-08-10
- Subjects:
- digital phantom -- digital reference object -- DRO -- DSC -- dynamic susceptibility contrast -- MRI -- quality assurance
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15125 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26727.xml