Feasibility of diffusion weighting with a local inside‐out nonlinear gradient coil for prostate MRI. Issue 10 (24th September 2021)
- Record Type:
- Journal Article
- Title:
- Feasibility of diffusion weighting with a local inside‐out nonlinear gradient coil for prostate MRI. Issue 10 (24th September 2021)
- Main Title:
- Feasibility of diffusion weighting with a local inside‐out nonlinear gradient coil for prostate MRI
- Authors:
- Hoque Bhuiyan, Enamul
Dewdney, Andrew
Weinreb, Jeffrey
Galiana, Gigi - Abstract:
- Abstract: Purpose: Prostate cancer remains the second leading cancer killer of men, yet it is also a disease with a high rate of overtreatment. Diffusion‐weighted imaging (DWI) has shown promise as a reliable, grade‐sensitive imaging method, but it is limited by low image quality. Currently, DWI quality image is directly related to low gradient amplitudes, since weak gradients must be compensated with long echo times. Methods: We propose a new type of MRI accessory, an "inside‐out" and nonlinear gradient, whose sole purpose is to deliver diffusion encoding to a region of interest. Performance was simulated in OPERA and the resulting fields were used to simulate DWI with two‐compartment and kurtosis models. Experiments with a nonlinear head gradient prove the accuracy of DWI and apparent diffusion coefficient (ADC) maps encoded with nonlinear gradients. Results: Simulations validated thermal and mechanical safety while showing a 5‐ to 10‐fold increase in gradient strength over prostate. With these strengths, lesion contrast to noise ratio in ADC maps approximately doubled for a range of anatomical positions. Proof‐of‐principle experiments show that spatially varying b‐values can be corrected for accurate DWI and ADC. Conclusions: Dedicated nonlinear diffusion encoding hardware could improve prostate DWI.
- Is Part Of:
- Medical physics. Volume 48:Issue 10(2021)
- Journal:
- Medical physics
- Issue:
- Volume 48:Issue 10(2021)
- Issue Display:
- Volume 48, Issue 10 (2021)
- Year:
- 2021
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2021-0048-0010-0000
- Page Start:
- 5804
- Page End:
- 5818
- Publication Date:
- 2021-09-24
- Subjects:
- apparent diffusion coefficient (ADC) -- diffusion‐weighted imaging (DWI) -- nonlinear gradient -- prostate cancer -- system design
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.15100 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26727.xml