Individual motion patterns during gait and sit-to-stand contribute to edge-loading risk in metal-on-metal hip resurfacing. (July 2013)
- Record Type:
- Journal Article
- Title:
- Individual motion patterns during gait and sit-to-stand contribute to edge-loading risk in metal-on-metal hip resurfacing. (July 2013)
- Main Title:
- Individual motion patterns during gait and sit-to-stand contribute to edge-loading risk in metal-on-metal hip resurfacing
- Authors:
- Mellon, Stephen J
Grammatopoulos, George
Andersen, Michael S
Pegg, Elise C
Pandit, Hemant G
Murray, David W
Gill, Harinderjit S - Abstract:
- The occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty has been associated with higher than normal bearing wear and high serum metal ion levels although both these findings do not necessarily coexist. The purpose of this study was to examine patient activity patterns and their influence on acetabular component edge loading in a group of subjects with known serum metal ion levels. Fifteen subjects with metal-on-metal hip resurfacing arthroplasty (eight males and seven females) were recruited for motion analysis followed by computed tomography scans. They were divided into three groups based on their serum metal ion levels and the orientation of their acetabular component: well-positioned acetabular component with low metal ions, mal-positioned acetabular component with low metal ions and mal-positioned acetabular component with high ions. A combination of motion analysis, subject-specific modelling (AnyBody Modeling System, Aalborg, Denmark) and computed tomography measurements was used to calculate dynamically the contact patch-to-rim distance for each subject during gait and sit-to-stand. The contact-pitch-to-rim distance for the high ion group was significantly lower ( p <0.001) than for the two low ion groups (well-positioned and mal-positioned) during the stance phase of gait (0%–60%) and loading phase of sit-to-stand (20%–80%). The results of this study, in particular, the significantThe occurrence of pseudotumours (soft tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty has been associated with higher than normal bearing wear and high serum metal ion levels although both these findings do not necessarily coexist. The purpose of this study was to examine patient activity patterns and their influence on acetabular component edge loading in a group of subjects with known serum metal ion levels. Fifteen subjects with metal-on-metal hip resurfacing arthroplasty (eight males and seven females) were recruited for motion analysis followed by computed tomography scans. They were divided into three groups based on their serum metal ion levels and the orientation of their acetabular component: well-positioned acetabular component with low metal ions, mal-positioned acetabular component with low metal ions and mal-positioned acetabular component with high ions. A combination of motion analysis, subject-specific modelling (AnyBody Modeling System, Aalborg, Denmark) and computed tomography measurements was used to calculate dynamically the contact patch-to-rim distance for each subject during gait and sit-to-stand. The contact-pitch-to-rim distance for the high ion group was significantly lower ( p <0.001) than for the two low ion groups (well-positioned and mal-positioned) during the stance phase of gait (0%–60%) and loading phase of sit-to-stand (20%–80%). The results of this study, in particular, the significant difference between the two mal-positioned groups, suggest that wear of metal-on-metal hip resurfacing arthroplasty is not only affected by acetabular cup orientation but also influenced by individual patient activity patterns. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 227:Number 7(2013)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 227:Number 7(2013)
- Issue Display:
- Volume 227, Issue 7 (2013)
- Year:
- 2013
- Volume:
- 227
- Issue:
- 7
- Issue Sort Value:
- 2013-0227-0007-0000
- Page Start:
- 799
- Page End:
- 810
- Publication Date:
- 2013-07
- Subjects:
- Kinematics -- hip -- metal-on-metal -- joint reaction force
Biomedical engineering -- Periodicals
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://pih.sagepub.com/ ↗
http://journals.pepublishing.com/content/119779 ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0954411913483639 ↗
- Languages:
- English
- ISSNs:
- 0954-4119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26732.xml