Incidence, mechanisms and clinical impact of largely uncovered struts in current generation drug-eluting-stents: insight from the TRANSFORM-OCT Study. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Incidence, mechanisms and clinical impact of largely uncovered struts in current generation drug-eluting-stents: insight from the TRANSFORM-OCT Study. (25th November 2020)
- Main Title:
- Incidence, mechanisms and clinical impact of largely uncovered struts in current generation drug-eluting-stents: insight from the TRANSFORM-OCT Study
- Authors:
- Bernelli, C
Pellegrini, D
Pescetelli, I
Garbo, R
Sirbu, V
Fiocca, L
Canova, P
Colombo, F
Cereda, A
Boccuzzi, G
Rodriguez Pereira, G.T
Bezerra, H
Saia, F
Capodanno, D
Guagliumi, G - Abstract:
- Abstract: Background: Thin-strut drug-eluting stents (DES) and optimal implantation technique reduce the rate of stent failure significantly. Nevertheless, uncovered struts (US) have been observed as a key factor for stent thrombosis regardless of stent generation and time of follow-up. Associated factors and temporal evolution are currently unknown. Purpose: To evaluate the prevalence, mechanisms and long-term clinical impact of largely-US after state-of-the-art DES implantation in complex coronary clinical/lesion cohorts Methods: The study was a pre-specified analysis of TRASFORM-OCT, a randomized controlled trial comparing bioabsorbable or durable polymer DES by serial optical coherence tomography (OCT), obtained at baseline, immediately after procedure, at 3 and 18 months follow-up. Methods and results were published previously. For the current analysis enrolled patients (n=90) were divided in 2 groups according to the amount of US identified by OCT at 3 months: a largely US (LUS ≥30%) group and the control group (<30% US), to evaluate factors associated to LUS, and the clinical impact at follow-up. Results: Out of 90 patients, 31 (34.4%) were assigned to the LUS group, and 59 (65.6%) to the control group. At baseline, LUS patients had larger vessels (reference area 5.51±1.1 vs. 4.27±1.5 mm 2, p=0.001), a higher rate of plaque rupture (41.9 vs. 18.6%, p=0.02), thin-cap fibroatheroma (58.1% vs. 51.7% p=0.03) and thrombus (58.1% vs. 35.6%, p=0.001) as detected by OCT. 98%Abstract: Background: Thin-strut drug-eluting stents (DES) and optimal implantation technique reduce the rate of stent failure significantly. Nevertheless, uncovered struts (US) have been observed as a key factor for stent thrombosis regardless of stent generation and time of follow-up. Associated factors and temporal evolution are currently unknown. Purpose: To evaluate the prevalence, mechanisms and long-term clinical impact of largely-US after state-of-the-art DES implantation in complex coronary clinical/lesion cohorts Methods: The study was a pre-specified analysis of TRASFORM-OCT, a randomized controlled trial comparing bioabsorbable or durable polymer DES by serial optical coherence tomography (OCT), obtained at baseline, immediately after procedure, at 3 and 18 months follow-up. Methods and results were published previously. For the current analysis enrolled patients (n=90) were divided in 2 groups according to the amount of US identified by OCT at 3 months: a largely US (LUS ≥30%) group and the control group (<30% US), to evaluate factors associated to LUS, and the clinical impact at follow-up. Results: Out of 90 patients, 31 (34.4%) were assigned to the LUS group, and 59 (65.6%) to the control group. At baseline, LUS patients had larger vessels (reference area 5.51±1.1 vs. 4.27±1.5 mm 2, p=0.001), a higher rate of plaque rupture (41.9 vs. 18.6%, p=0.02), thin-cap fibroatheroma (58.1% vs. 51.7% p=0.03) and thrombus (58.1% vs. 35.6%, p=0.001) as detected by OCT. 98% patients continued dual antiplatelet therapy up to 12 months, and 24% of them up to 18 months. At stent implant, performed with high pressure dilation (21.18±3.8 vs 20.54±3.6 atm in LUS vs control group, p 0.48), the rate of apposed and embedded struts was high in both groups, although higher in controls (93.92±5.30% vs 96.46±3.68%, p 0.03 and 16.8±11.5% vs 21.7±15.8%, p=0.12, respectively for controls and LUS). At 3 months, US rate was 48.4±12% in the LUS group, and 13.3±7% in the control group (p<0.001). Global malapposition rate was 7.95±7.5% and 1.69±1.6% (p<0.001), respectively. 84.52±12.41% of the US in the LUS group and 86.49±19.98% in controls group were apposed to the wall (p 0.07). At 18 months, the rate of US dropped significantly to 8.4±10% in LUS group and 1.8±3% in control group (p<0.001), with malapposition rate being 1.4±3.3 and 0.16±0.43% (p 0.006). Of the US, 81.6±25.15 and 91.11±21.76% were apposed to the wall, respectively. At 5 years clinical follow-up, no differences were observed at the composite endpoint of major adverse cardiovascular events (detailed data will be presented). Conclusions: In a setting of optimal PCI with modern DES and high-pressure inflation, LUS occur in 30% of patients at early follow-up, more frequently in large vessels with lipid-rich, complex plaques. The vast majority of US is apposed to the wall and near-complete coverage is observed at long-term follow-up, with no clinical impact compared to subjects with a low rate of US. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Optical Coherence Tomography
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.2474 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26725.xml