Feasibility of virtual fractional flow reserve derived from coronary angiography and its correlation with invasive functional assessment. (14th October 2021)
- Record Type:
- Journal Article
- Title:
- Feasibility of virtual fractional flow reserve derived from coronary angiography and its correlation with invasive functional assessment. (14th October 2021)
- Main Title:
- Feasibility of virtual fractional flow reserve derived from coronary angiography and its correlation with invasive functional assessment
- Authors:
- Mano, T
Ferreira, V
Ramos, R
Oliveira, E
Santana, A
Melo, J
Reis, J
Bras, P
Teixeira, B
Cardoso, I
Castelo, A
Cacela, D
Cruz Ferreira, R - Abstract:
- Abstract: Introduction: Invasive functional assessment (iFA) of coronary artery disease (CAD) needs expensive devices, has potential procedure-related complications and is still underutilized. Virtual Fractional Flow Reserve (vFFR) derived from invasive coronary angiography (ICA) has the potential to overcome these limitations. Purpose: To investigate the feasibility of vFFR analysis and its correlation with iFA (iFR, RFR or FFR). Methods: Retrospective analysis of consecutive patients (pts) who underwent iFA in a tertiary center between 2019 and 2020. vFFR was calculated using a dedicated software (CAAS Workstation 8.4) based on standard non-hyperaemic coronary angiograms acquired in ≥2 different projections, by operators blinded to iFA results. Diagnostic performance and accuracy of vFFR were evaluated. vFFR was considered positive when <0.80. FFR <0.8 and iFR/RFR <0.90 were classified as positive according to current clinical standards. Results: Out of 113 coronary arteries of 102 pts, vFFR was successfully analysed in 106 (94%). Reasons for vFFR analysis failure were: vessel projection overlap (48%), <2 angiographic projections (28%) and table movement while acquisition (24%). From 106 coronary arteries of 95 pts with analysable vFFR (78% male, mean age 67.8±9.7 years), 90 (85%) showed agreement with the respective iFA result. The vFFR predicted which lesions were physiologically significant and which were not with accuracy, sensitivity, specificity, positive andAbstract: Introduction: Invasive functional assessment (iFA) of coronary artery disease (CAD) needs expensive devices, has potential procedure-related complications and is still underutilized. Virtual Fractional Flow Reserve (vFFR) derived from invasive coronary angiography (ICA) has the potential to overcome these limitations. Purpose: To investigate the feasibility of vFFR analysis and its correlation with iFA (iFR, RFR or FFR). Methods: Retrospective analysis of consecutive patients (pts) who underwent iFA in a tertiary center between 2019 and 2020. vFFR was calculated using a dedicated software (CAAS Workstation 8.4) based on standard non-hyperaemic coronary angiograms acquired in ≥2 different projections, by operators blinded to iFA results. Diagnostic performance and accuracy of vFFR were evaluated. vFFR was considered positive when <0.80. FFR <0.8 and iFR/RFR <0.90 were classified as positive according to current clinical standards. Results: Out of 113 coronary arteries of 102 pts, vFFR was successfully analysed in 106 (94%). Reasons for vFFR analysis failure were: vessel projection overlap (48%), <2 angiographic projections (28%) and table movement while acquisition (24%). From 106 coronary arteries of 95 pts with analysable vFFR (78% male, mean age 67.8±9.7 years), 90 (85%) showed agreement with the respective iFA result. The vFFR predicted which lesions were physiologically significant and which were not with accuracy, sensitivity, specificity, positive and negative predictive values of 73%, 73%, 83%, 53%, and 92% respectively. The mean difference between vFFR and iFA were −0.0484±0.096 and Pearson's correlation coefficient was 0.533 (p<0.001). The ROC area under the curve was 0.839 (0.751–0.928, p<0.001). Conclusion: FFR were feasible in 94% of cases analysed retrospectively. As compared to gold-standard iFA, vFFR had an overall moderate accuracy in detecting ischemia-producing lesions and a negative predictive value >90%. vFFR has the potential to substantially simplify physiological coronary lesion assessment and thus improve its current uptake. Funding Acknowledgement: Type of funding sources: None. … (more)
- Is Part Of:
- European heart journal. Volume 42(2021)Supplement 1
- Journal:
- European heart journal
- Issue:
- Volume 42(2021)Supplement 1
- Issue Display:
- Volume 42, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 42
- Issue:
- 1
- Issue Sort Value:
- 2021-0042-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-10-14
- Subjects:
- Intracoronary Flow and Pressure Measurements
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/eurheartj/ehab724.1196 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26723.xml