Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma. Issue 3 (March 2022)
- Record Type:
- Journal Article
- Title:
- Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma. Issue 3 (March 2022)
- Main Title:
- Effects of Corneal Biomechanical Properties on Rebound Tonometry (Icare200) and Applanation Tonometry (Perkins) Readings in Patients With Primary Congenital Glaucoma
- Authors:
- Morales-Fernandez, Laura
Saenz-Frances, Federico
Pérez-García, Pilar
Garcia-Feijoo, Julian
Garcia-Saenz, Sofia
Gómez de Liaño, Rosario
Martinez-de-la-Casa, Jose M. - Abstract:
- Abstract : Objective: The aim was to assess the influence of corneal biomechanics on intraocular pressure (IOP) measurements made with the Icare200 (IC200) rebound tonometer and the Perkins handheld applanation tonometer in patients with primary congenital glaucoma (PCG). Materials and Methods: A total of 40 PCG patients and 40 healthy controls, age, and sex-matched, were recruited. IOP was measured with the Ocular Response Analyzer (IOPc, IOPg), IC200 and Perkins. The variables age, IOP, corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), best-corrected visual acuity, spherical equivalent, medications, and glaucoma surgeries were recorded for each subject. Univariate and multivariate analysis were used to detect effects of variables on IOP measurements. Results: Mean CCT was 545.65±71.88 μm in PCG versus 558.78±27.58 μm in controls ( P =0.284). CH and CRF were significantly lower in PCG group than in control group: mean CH 8.11±1.69 versus 11.15±1.63 mm Hg ( P <0.001), and mean CRF 9.27±2.35 versus 10.71±1.75 mm Hg ( P =0.002). Mean differences between IOP IC200-Perkins were 0.79±0.53 mm Hg in PCG versus 0.80±0.23 mm Hg in controls ( P <0.001) and mean differences IC200-IOPc were −0.89±5.15 mm Hg in PCG ( P <0.001) versus 1.60±3.03 mm Hg in controls (all P <0.009). Through multivariate analysis, CRF showed positive association and CH negative association with IOP measured with Perkins or IC200 in both subject groups. No association wasAbstract : Objective: The aim was to assess the influence of corneal biomechanics on intraocular pressure (IOP) measurements made with the Icare200 (IC200) rebound tonometer and the Perkins handheld applanation tonometer in patients with primary congenital glaucoma (PCG). Materials and Methods: A total of 40 PCG patients and 40 healthy controls, age, and sex-matched, were recruited. IOP was measured with the Ocular Response Analyzer (IOPc, IOPg), IC200 and Perkins. The variables age, IOP, corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), best-corrected visual acuity, spherical equivalent, medications, and glaucoma surgeries were recorded for each subject. Univariate and multivariate analysis were used to detect effects of variables on IOP measurements. Results: Mean CCT was 545.65±71.88 μm in PCG versus 558.78±27.58 μm in controls ( P =0.284). CH and CRF were significantly lower in PCG group than in control group: mean CH 8.11±1.69 versus 11.15±1.63 mm Hg ( P <0.001), and mean CRF 9.27±2.35 versus 10.71±1.75 mm Hg ( P =0.002). Mean differences between IOP IC200-Perkins were 0.79±0.53 mm Hg in PCG versus 0.80±0.23 mm Hg in controls ( P <0.001) and mean differences IC200-IOPc were −0.89±5.15 mm Hg in PCG ( P <0.001) versus 1.60±3.03 mm Hg in controls (all P <0.009). Through multivariate analysis, CRF showed positive association and CH negative association with IOP measured with Perkins or IC200 in both subject groups. No association was detected for CCT, age, or sex. Conclusion: CH and CRF were identified as the main factors interfering with IOP measurements made with both tonometers in patients with PCG and healthy controls. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 31:Issue 3(2022)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 31:Issue 3(2022)
- Issue Display:
- Volume 31, Issue 3 (2022)
- Year:
- 2022
- Volume:
- 31
- Issue:
- 3
- Issue Sort Value:
- 2022-0031-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2022-03
- Subjects:
- primary congenital glaucoma -- tonometry -- biomechanical corneal properties -- hysteresis -- rebound tonometer -- Icare200 -- Ocular Response Analyzer -- Perkins applanation tonometer -- central corneal thickness
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000001913 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26705.xml