Biodegradable-polymer versus durable-polymer drug eluting stents for coronary artery disease: systematic review and a meta-analysis. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Biodegradable-polymer versus durable-polymer drug eluting stents for coronary artery disease: systematic review and a meta-analysis. (25th November 2020)
- Main Title:
- Biodegradable-polymer versus durable-polymer drug eluting stents for coronary artery disease: systematic review and a meta-analysis
- Authors:
- Toyota, T
Morimoto, T
Kitai, T
Park, M
Sasaki, Y
Kim, K
Ehara, N
Kobori, A
Kinoshita, M
Kaji, S
Furukawa, Y
Kimura, T - Abstract:
- Abstract: Background: Biodegradable polymer drug-eluting stents (BP-DES) has been developed to overcome the potential drawbacks of the first-generation durable polymer drug-eluting stents (DP-DES). However, it is still under debate whether BP-DES is associated with superior efficacy and safety over DP-DES. Purpose: We sought to compare the effects of BP-DES and DP-DES in patients with coronary artery disease. Methods: We performed systematic review and a meta-analysis of randomized controlled trials comparing BP-DES and DP-DES on clinical outcomes in patients with coronary artery disease using CE-mark approved drug-eluting stents (DES) with at least 1-year follow-up. We included 32 studies involving 39, 686 patients (BP-DES: 21, 439 patients, and DP-DES: 18, 247 patients). Primary outcome measure was target vessel failure (TVF; equivalent to the composite of cardiac death, target-vessel myocardial infarction, or ischemia-driven target vessel revascularization). We performed subgroup analysis according to the DP-DES generations (newer-generation DP-DES: 15, 179patients, and first-generation DP-DES: 3, 068 patients), and the effects of newer-generation DP-DES was compared with the BP-DES according to the BP-DES strut thickness (Ultra-thin strut [<80μm]: 7, 572 patients, Thin-strut [80–100μm]: 5, 465 patients, and Thick-strut [≥80μm]: 5, 876 patients). Results: The odds for TVF was not significantly different between the BP-DES group and the DP-DES group in the entire studyAbstract: Background: Biodegradable polymer drug-eluting stents (BP-DES) has been developed to overcome the potential drawbacks of the first-generation durable polymer drug-eluting stents (DP-DES). However, it is still under debate whether BP-DES is associated with superior efficacy and safety over DP-DES. Purpose: We sought to compare the effects of BP-DES and DP-DES in patients with coronary artery disease. Methods: We performed systematic review and a meta-analysis of randomized controlled trials comparing BP-DES and DP-DES on clinical outcomes in patients with coronary artery disease using CE-mark approved drug-eluting stents (DES) with at least 1-year follow-up. We included 32 studies involving 39, 686 patients (BP-DES: 21, 439 patients, and DP-DES: 18, 247 patients). Primary outcome measure was target vessel failure (TVF; equivalent to the composite of cardiac death, target-vessel myocardial infarction, or ischemia-driven target vessel revascularization). We performed subgroup analysis according to the DP-DES generations (newer-generation DP-DES: 15, 179patients, and first-generation DP-DES: 3, 068 patients), and the effects of newer-generation DP-DES was compared with the BP-DES according to the BP-DES strut thickness (Ultra-thin strut [<80μm]: 7, 572 patients, Thin-strut [80–100μm]: 5, 465 patients, and Thick-strut [≥80μm]: 5, 876 patients). Results: The odds for TVF was not significantly different between the BP-DES group and the DP-DES group in the entire study population (odds ratio [OR] 0.96, 95% confidence interval [CI] [0.90–1.02], P=0.20). The odds for TVF was significantly low in the BP-DES group relative to the first-generation DP-DES group, however the odds were comparable between the BP-DES group and the newer-generation DP-DES group (BP-DES versus first-generation DP-DES: OR 0.82, 95% CI [0.73–0.92], P<0.001, and BP-DES versus newer-generation DP-DES: OR 1.00, 95% CI [0.93–1.08], P=0.99). We also found no significant differences between the BP-DES and newer-generation DP-DES, in all subgroups stratified by the BP-DES strut thickness (Ultra-thin strut BP-DES versus newer-generation DP-DES: OR 0.88, 95% CI [0.76–1.02], P=0.10, Thin-strut BP-DES versus newer-generation DP-DES: OR 1.01, 95% CI [0.90–1.13], P=0.89, and Thick strut BP-DES versus newer-generation DP-DES: OR 1.11, 95% CI [0.99–1.25], P=0.08). Conclusions: In this meta-analysis of randomized controlled trials evaluating clinical outcomes, there was no significant differences between BP-DES and DP-DES. We found beneficial effects of BP-DES relative to the first-generation DP-DES, however, there was no statistical differences between BP-DES and newer-generation DP-DES, irrespective of the BP-DES strut thickness. Funding Acknowledgement: Type of funding source: None … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Coronary Intervention: Stents
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.2540 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26724.xml