Long-term outcomes of the micronet-covered stent system routine use for carotid revsacularization in stroke prevention: PARADIGM-Extend 5 year evidence. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Long-term outcomes of the micronet-covered stent system routine use for carotid revsacularization in stroke prevention: PARADIGM-Extend 5 year evidence. (25th November 2020)
- Main Title:
- Long-term outcomes of the micronet-covered stent system routine use for carotid revsacularization in stroke prevention: PARADIGM-Extend 5 year evidence
- Authors:
- Mazurek, A
Borratynska, A
Tomaszewski, T
Lesniak-Sobelga, A
Wilkolek, P
Gancarczyk, U
Brozda, M
Sobieraj, E
Sikorska, M
Czyz, L
Urbanczyk, M
Trystula, M
Drazkiewicz, T
Podolec, P
Musialek, P - Abstract:
- Abstract: Background: Diffusion-weighted magnetic resonance imaging indicates that micronet-covered embolic prevention stent system effectively minimizes peri-procedural and prevents lesion-related post-procedural cerebral embolism in carotid artery stenting but long-term clinical evidence is missing. Purpose: To provide long-term clinical and duplex ultrasound evaluation of safety and efficacy of the system use in consecutive carotid revascularization patients. Methods: PARADIGM-EXTEND is in all-comer, all-referrals-tracked study with no exclusion criteria other than lack of NeuroVascular Team-determined indication. Clinically asymptomatic patients receive revascularization only in case of increased-stroke-risk characteristics. Adverse events are independently adjudicated. Results: Currently 451 patients (48–87 years, 59% symptomatic, 127 women) with 490 arteries crossed the first follow-up window of 30 days. There has been 100% micronet-covered embolic prevention stent system use (ie, no other stent type/s used throughout study). Proximal/distal intra-procedural neuroprotection use was 38.3%/61.7%. Large balloon/high-pressure stent optimization was routine, leading to a single-digit (mean 6.9%) residual diameter stenosis. Independent neurologist and duplex evaluation are before and after revascularization (48h and 30 days, then yearly). Peri-procedural death or major ischemic stroke rate was 0%. One event (prior infarct scar asymptomatic extension in prolonged hypotensionAbstract: Background: Diffusion-weighted magnetic resonance imaging indicates that micronet-covered embolic prevention stent system effectively minimizes peri-procedural and prevents lesion-related post-procedural cerebral embolism in carotid artery stenting but long-term clinical evidence is missing. Purpose: To provide long-term clinical and duplex ultrasound evaluation of safety and efficacy of the system use in consecutive carotid revascularization patients. Methods: PARADIGM-EXTEND is in all-comer, all-referrals-tracked study with no exclusion criteria other than lack of NeuroVascular Team-determined indication. Clinically asymptomatic patients receive revascularization only in case of increased-stroke-risk characteristics. Adverse events are independently adjudicated. Results: Currently 451 patients (48–87 years, 59% symptomatic, 127 women) with 490 arteries crossed the first follow-up window of 30 days. There has been 100% micronet-covered embolic prevention stent system use (ie, no other stent type/s used throughout study). Proximal/distal intra-procedural neuroprotection use was 38.3%/61.7%. Large balloon/high-pressure stent optimization was routine, leading to a single-digit (mean 6.9%) residual diameter stenosis. Independent neurologist and duplex evaluation are before and after revascularization (48h and 30 days, then yearly). Peri-procedural death or major ischemic stroke rate was 0%. One event (prior infarct scar asymptomatic extension in prolonged hypotension course) was adjudicated as minor stroke (0.22%), and there was 1 periprocedural MI (type 2, in 2-vessel non-revascularizable CTO; 0.22%). By 30 days there were no further ischaemic strokes (0%) but there was 1 haemorrhagic transformation that led to death (0.22%) and 1 bleeding-related death (0.22%). Thus total 30-day death/stroke was 0.66%, and total death/stroke/MI was 0.88%. By 60 months there were 3 contralateral, 1 ipsilateral (device-unrelated), and 2 posterior circulation strokes. Baseline internal carotid artery velocities were 3.72±1.25 and 0.63±0.69 m/s (peak-systolic and end-diastolic). Post-procedural in-stent velocities were normal and remained normal throughout the 60-month follow-up period: 0.78±040 and 0.21±0.10 (1y); 0.75±0.36 0.19±0.09 (2y); 0.75±0, 35 and 0.21±0.09 (3y); 0.72±0.27 and 0.20±0.07 (4y); 0.79±0.58 and 0.21±0.11m/s (5y). There were 2 in-stent restenoses by 1y (including 1 that occurred with de novo neck radiotherapy) and 1 other by 2y (total 2y in-stent restenosis of 1.1%) but no further ones (0% in-stent restenosis at 2–5y). Conclusions: PARADIGM-Extend long-term clinical and duplex ultrasound evidence is consistent with normal healing and sustained safety and stroke prevention efficacy of the micronet-covered embolic prevention stent system used routinely, on top of optimized medical therapy, for stroke prevention in symptomatic and increased-stroke-risk asymptomatic subjects with carotid stenosis recommended for revasularization by the NeuroVascular Team. Funding Acknowledgement: Type of funding source: Public Institution(s). Main funding source(s): Jagiellonian University Medical College … (more)
- Is Part Of:
- European heart journal. Volume 41:(2020)Supplement 2
- Journal:
- European heart journal
- Issue:
- Volume 41:(2020)Supplement 2
- Issue Display:
- Volume 41, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2020-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- Carotid Disease
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.12005 - Journal URLs:
- http://eurheartj.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ehjci/ehaa946.2404 ↗
- Languages:
- English
- ISSNs:
- 0195-668X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.717500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26694.xml