Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment. (1st December 2018)
- Record Type:
- Journal Article
- Title:
- Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment. (1st December 2018)
- Main Title:
- Efficacy of cryoballoon ablation in patients with paroxysmal atrial fibrillation without time to pulmonary vein isolation assessment
- Authors:
- Stabile, Giuseppe
Tondo, Claudio
Curnis, Antonio
Lunati, Maurizio
Manfrin, Massimiliano
Molon, Giulio
Sciarra, Luigi
Mantica, Massimo
Iacopino, Saverio
Arena, Giuseppe
Landolina, Maurizio
Arestia, Alberto
Verlato, Roberto - Abstract:
- Abstract: Background: Real-time visualization of the electrical activity of the pulmonary veins (PV) is not always possible in the setting of atrial fibrillation (AF) cryoballoon ablation. We investigated the relation between the effective documentation of time to PV isolation and the clinical outcome in a cohort of patients with paroxysmal AF who underwent cryoballoon ablation. Methods: One thousand forty two consecutive patients were enrolled. An inner lumen mapping catheter was typically used to visualize real-time electrical activity inside the PVs. Results: Time to PV isolation was documented in all targeted PVs in 391 patients (Group 1), in 651 patients it was not possible to record PV potentials and assess time to PV isolation in at least one PV (Group 2). In Group 1 a longer procedure duration and ablation time were observed, while a longer fluoroscopy time was observed in Group 2. After a mean follow-up of 14 ± 11 months, 209/1042 (20%) patients had an atrial arrhythmia recurrence (20.2% in Group 1, 19.9% in Group 2, p = 0.25). Complications occurred in 54/1042 (5.2%) patients without any difference among the two study groups. Conclusion: In our retrospective analysis, in about two thirds of patients undergoing cryoballoon ablation it was not possible to acutely assess time to PV isolation in all PVs. However, one-year freedom from clinically symptomatic atrial tachyarrhythmia was similar to that of patients in which time to PV isolation was documented in allAbstract: Background: Real-time visualization of the electrical activity of the pulmonary veins (PV) is not always possible in the setting of atrial fibrillation (AF) cryoballoon ablation. We investigated the relation between the effective documentation of time to PV isolation and the clinical outcome in a cohort of patients with paroxysmal AF who underwent cryoballoon ablation. Methods: One thousand forty two consecutive patients were enrolled. An inner lumen mapping catheter was typically used to visualize real-time electrical activity inside the PVs. Results: Time to PV isolation was documented in all targeted PVs in 391 patients (Group 1), in 651 patients it was not possible to record PV potentials and assess time to PV isolation in at least one PV (Group 2). In Group 1 a longer procedure duration and ablation time were observed, while a longer fluoroscopy time was observed in Group 2. After a mean follow-up of 14 ± 11 months, 209/1042 (20%) patients had an atrial arrhythmia recurrence (20.2% in Group 1, 19.9% in Group 2, p = 0.25). Complications occurred in 54/1042 (5.2%) patients without any difference among the two study groups. Conclusion: In our retrospective analysis, in about two thirds of patients undergoing cryoballoon ablation it was not possible to acutely assess time to PV isolation in all PVs. However, one-year freedom from clinically symptomatic atrial tachyarrhythmia was similar to that of patients in which time to PV isolation was documented in all targeted veins. Clinical Trial Registration: clinicaltrials.gov (NCT01007474 ). Highlights: Real-time visualization of the electrical activity of the pulmonary veins is not always possible in the setting of AF cryoablation. In the 63% of patients it was not possible to acutely assess time to pulmonary vein isolation in all targeted pulmonary veins. One-year freedom from atrial tachyarrhythmia was similar to that of patients in which time to PV isolation was documented in all targeted veins. … (more)
- Is Part Of:
- International journal of cardiology. Volume 272(2018)
- Journal:
- International journal of cardiology
- Issue:
- Volume 272(2018)
- Issue Display:
- Volume 272, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 272
- Issue:
- 2018
- Issue Sort Value:
- 2018-0272-2018-0000
- Page Start:
- 118
- Page End:
- 122
- Publication Date:
- 2018-12-01
- Subjects:
- Atrial fibrillation -- Catheter ablation -- Cryoballoon -- Pulmonary vein isolation -- Mid-term outcome
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2018.07.070 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 26700.xml